首页> 外文期刊>Radiation measurements >A radioactive contamination monitoring system with a bead-type radiophotoluminescence glass dosimeter
【24h】

A radioactive contamination monitoring system with a bead-type radiophotoluminescence glass dosimeter

机译:带有珠型放射光致发光玻璃剂量计的放射性污染监测系统

获取原文
获取原文并翻译 | 示例
           

摘要

A radiophotoluminescence (RPL) monitoring scope system was constructed to evaluate radioactive cesium contamination. RPL glass sheets were constructed by bonding RPL glass beads to a backing sheet. The RPL scope was constructed using an image intensifier and a CCD camera to detect RPL from the RPL glass sheet. A UV floodlight was also prepared as an excitation light source. The UV floodlight and an image intensifier were pulse-operated for high signal-to-noise RPL detection. In experiments, the RPL of X-ray irradiated glass sheets was measured with this present system. The RPL intensity, which is calculated from the brightness of obtained images, exhibits acceptable linearity to the absorbed dose. Another experiment showed that RPL can be detected at a distance of 10 m between the RPL glass sheets and the RPL detector. (C) 2016 Elsevier Ltd. All rights reserved.
机译:构建了放射性光致发光(RPL)监测镜系统,以评估放射性铯的污染。 RPL玻璃板是通过将RPL玻璃珠粘结到背板上来构造的。使用图像增强器和CCD摄像机构造RPL示波器,以从RPL玻璃板上检测RPL。还准备了紫外线探照灯作为激发光源。紫外线泛光灯和图像增强器通过脉冲操作进行高信噪比RPL检测。在实验中,用本系统测量了X射线辐射玻璃板的RPL。由获得的图像的亮度计算得出的RPL强度与吸收剂量呈线性关系。另一个实验表明,可以在RPL玻璃板和RPL检测器之间的10 m距离处检测RPL。 (C)2016 Elsevier Ltd.保留所有权利。