Monte-Carlo simulations of Al_2O_3 dosimetry in uniform MV photon beams: Influence of field and detector size

机译:均匀MV光子束中Al_2O_3剂量学的蒙特卡洛模拟:场和探测器尺寸的影响

获取原文
获取原文并翻译 | 示例
           

摘要

This work was to evaluate the absorbed dose to different sizes Al_2O_3 dosimeter in uniform MV photon beams using Monte Carlo simulation. The absorbed dose ratio factor f md of Al_2O_3 dosimeters was calculated. The incident beams included 4 MV-24 MV X-rays using Mohan's spectra with different field sizes. Results show that the maximum variation of f md due to different dosimeter sizes is 5%. As the field diameter increases from 1 cm to 3 cm, the difference of f md can be up to 8%. The results of this work show that the effect of dosimeter size and the field size can't be neglected when using Al_2O_3 dosimeter.
机译:这项工作是使用蒙特卡洛模拟评估在均匀MV光子束中不同尺寸Al_2O_3剂量计的吸收剂量。计算了Al_2O_3剂量计的吸收剂量比因子f md。入射光束包括4张MV-24 MV X射线,这些X射线使用Mohan光谱并具有不同的场大小。结果表明,由于剂量计大小不同,f md的最大变化为5%。随着视场直径从1厘米增加到3厘米,f md的差异可以达到8%。这项工作的结果表明,使用Al_2O_3剂量计不能忽略剂量计尺寸和场尺寸的影响。