The influence of geometry model approximations on Geant4 Monte Carlo simulation results of the radiation environment on-board the Columbus module of the International Space Station (ISS) has been investigated. Three geometry models of Columbus with different levels of detail and a geometry model of ISS have been developed. These geometries have been used for Geant4 simulations of the radiation environment inside Columbus induced by trapped protons and Galactic Cosmic Ray protons. Simulated dose rates and particle spectra on-board Columbus for each of the three Columbus models, with or without the ISS geometry model included, are presented and compared. From comparisons of simulated dose rates and particle spectra for the three different geometry models it was found that the most detailed geometry model (750 volumes) produced results similar to a much less detailed model (23 volumes). The most detailed geometry model was concluded to be a sufficiently detailed approximation of the physical Columbus for the purpose of proton induced space radiation studies. The simulated dose rates are compatible with measurements on-board the ISS. The simulation results also show that an increase in shielding thickness decreases the simulated dose rate induced by trapped protons. For Galactic Cosmic Ray protons the dose rate remains unchanged or is slightly increased. (c) 2007 Elsevier Ltd. All rights reserved.
机译:研究了几何模型近似对国际空间站(ISS)哥伦布模块上辐射环境的Geant4 Monte Carlo模拟结果的影响。已经开发了三种具有不同详细程度的哥伦布几何模型和ISS几何模型。这些几何形状已用于Geant4模拟由捕获质子和银河系宇宙射线质子诱发的哥伦布内部的辐射环境。呈现并比较了三种哥伦布模型(包括或不包括ISS几何模型)中每个模型的模拟剂量率和颗粒在哥伦布上的光谱。通过对三种不同几何模型的模拟剂量率和粒子光谱的比较,发现最详细的几何模型(750册)产生的结果类似于不太详细的模型(23册)。得出结论,最详细的几何模型是物理哥伦布的足够详细的近似值,用于质子诱发的空间辐射研究。模拟剂量率与ISS上的测量结果兼容。仿真结果还表明,屏蔽层厚度的增加会降低由捕获质子引起的模拟剂量率。对于银河宇宙射线质子,剂量率保持不变或略有增加。 (c)2007 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号