首页> 外文期刊>Respiratory medicine >An audit into the efficacy of single use bacterial/viral filters for the prevention of equipment contamination during lung function assessment.
【24h】

An audit into the efficacy of single use bacterial/viral filters for the prevention of equipment contamination during lung function assessment.

机译:对一次性使用的细菌/病毒过滤器在预防肺功能评估期间预防设备污染的功效进行审核。

获取原文
获取原文并翻译 | 示例

摘要

Lung function testing has been suggested to provide a potential risk regarding cross-infection between patients. About 155 patients (86 infectious, 69 non-infectious) used a single use bacterial/viral filter when performing routine lung function tests. Swabs from the patient side of the filter (Proximal) and the equipment side (Distal), and two sections of the filter itself were cultured. About 33/155 samples showed bacterial growth on the Proximal compared with 2/155 on the Distal side (P<0.01). Growth was obtained from the filter in 125/155 (80.6%) of cases. Pathogenic micro-organisms such as Pseudomonas aeruginosa (4 cases) and Staphylococcus aureus (5 cases) were isolated. Appropriate infection control measures should be used when performing lung function tests.
机译:有人建议进行肺功能检查,以提供有关患者之间交叉感染的潜在风险。进行常规肺功能检查时,约有155名患者(86例感染,69例非感染)使用了一次性细菌/病毒过滤器。培养了过滤器患者侧(近端)和设备侧(远端)的拭子,以及过滤器本身的两个部分。大约33/155个样品在近端显示细菌生长,而在远端则为2/155(P <0.01)。在125/155(80.6%)的情况下,从过滤器中获得了生长。分离出诸如铜绿假单胞菌(4例)和金黄色葡萄球菌(5例)等病原微生物。进行肺功能检查时,应使用适当的感染控制措施。