PURPOSE: To describe a new instrument, the subretinal aspiration and injection device (SR-AID), designed to facilitate the controlled external drainage or injection of fluid in the subretinal space. METHODS: The SR-AID is formed by an assembly of a probe, handle body, and a driving unit. The curved conduit within the probe segment forms a curved tunnel and acts as a guide along which a needle moves back and forth. The feasibility of fluid injection beneath the attached retina was tested in animal eyes. The efficacy of subretinal fluid drainage with the SR-AID were assessed in six cases of clinical retinal detachment. RESULTS: External approach to the subretinal space under ophthalmoscopic monitoring can be achieved by oblique angle penetration of the scleral wall with a needle from the SR-AID. Fluid was injected successfully into the subretinal space in three of six rabbit eyes and in two of two pig eyes. The mean duration required for the drainage of subretinal fluid with the SR-AID was 127 seconds. There was no incidence of significant subretinal hemorrhage or retinal perforation in the animal experiments and in human cases. CONCLUSION: Our case series suggests that the SR-AID provides an efficient and safe means of access to the subretinal space.
机译:目的:描述一种新的仪器,视网膜下抽吸和注射装置(SR-AID),其设计用于促进视网膜下腔内液体的受控外部引流或注射。方法:SR-AID由​​探针,手柄主体和驱动单元组成。探针段内的弯曲导管形成弯曲通道,并充当引导器,针沿着该引导器来回移动。在动物眼中测试了在附着的视网膜下方注入液体的可行性。在6例临床视网膜脱离患者中评估了使用SR-AID进行视网膜下引流的疗效。结果:在眼底镜监测下,通过使用SR-AID的针对巩膜壁进行斜角穿透可以实现对视网膜下间隙的外部入路。将液体成功注入六只兔子眼中的三只和两只两只猪眼中的两只至视网膜下腔。用SR-AID排出视网膜下液所需的平均持续时间为127秒。在动物实验和人类病例中,均未发现明显的视网膜下出血或视网膜穿孔。结论:我们的病例系列表明,SR-AID提供了一种有效且安全的进入视网膜下腔的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号