首页> 外文期刊>Radiotherapy and oncology: Journal of the European Society for Therapeutic Radiology and Oncology >The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide.
【24h】

The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide.

机译:欧洲放射治疗与肿瘤学会-欧洲放射治疗学会(ESTRO-EIR)报告了基于3D CT的室内图像导航系统:实用和技术审查与指南。

获取原文
获取原文并翻译 | 示例
           

摘要

The past decade has provided many technological advances in radiotherapy. The European Institute of Radiotherapy (EIR) was established by the European Society of Therapeutic Radiology and Oncology (ESTRO) to provide current consensus statement with evidence-based and pragmatic guidelines on topics of practical relevance for radiation oncology. This report focuses primarily on 3D CT-based in-room image guidance (3DCT-IGRT) systems. It will provide an overview and current standing of 3DCT-IGRT systems addressing the rationale, objectives, principles, applications, and process pathways, both clinical and technical for treatment delivery and quality assurance. These are reviewed for four categories of solutions; kV CT and kV CBCT (cone-beam CT) as well as MV CT and MV CBCT. It will also provide a framework and checklist to consider the capability and functionality of these systems as well as the resources needed for implementation. Two different but typical clinical cases (tonsillar and prostate cancer) using 3DCT-IGRT are illustrated with workflow processes via feedback questionnaires from several large clinical centres currently utilizing these systems. The feedback from these clinical centres demonstrates a wide variability based on local practices. This report whilst comprehensive is not exhaustive as this area of development remains a very active field for research and development. However, it should serve as a practical guide and framework for all professional groups within the field, focussed on clinicians, physicists and radiation therapy technologists interested in IGRT.
机译:过去的十年在放射治疗方面提供了许多技术进步。欧洲放射治疗学会(ESTRO)成立了欧洲放射治疗学会(EIR),旨在就放射肿瘤学的实际相关主题为当前共识性声明提供基于证据和务实的指南。本报告主要关注基于3D CT的室内图像导航(3DCT-IGRT)系统。它将概述3DCT-IGRT系统并概述其现状,现状,目标,原则,原理,应用和过程途径,包括用于治疗的临床和技术以及质量保证。针对四类解决方案进行了审查; kV CT和kV CBCT(锥形束CT)以及MV CT和MV CBCT。它还将提供框架和清单,以考虑这些系统的功能和功能以及实施所需的资源。通过来自当前使用这些系统的几个大型临床中心的反馈调查表,通过工作流程说明了使用3DCT-IGRT的两种不同但典型的临床案例(扁桃体和前列腺癌)。这些临床中心的反馈表明,根据当地实际情况存在很大差异。该报告虽然全面,但并不详尽,因为该领域的发展仍然是研究和开发的非常活跃的领域。但是,它应该作为该领域内所有专业人士的实用指南和框架,重点关注对IGRT感兴趣的临床医生,物理学家和放射治疗技术人员。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号