首页> 外文期刊>Reproductive biomedicine online >Standardization of catheter load speed during embryo transfer: Comparison of manual and pump-regulated embryo transfer
【24h】

Standardization of catheter load speed during embryo transfer: Comparison of manual and pump-regulated embryo transfer

机译:胚胎移植过程中导管加载速度的标准化:手动和泵控制的胚胎移植的比较

获取原文
获取原文并翻译 | 示例
           

摘要

The position of transfer air bubbles after embryo transfer is related to the pregnancy rate. With the conventional manual embryo-transfer technique it is not possible to predict the final position of the air bubbles. This position mainly depends on the catheter load speed at transfer (injection speed), a parameter that remains uncontrollable with the conventional technique even after standardization of the protocol. Therefore, the development of an automated device that generates a standardized injection speed is desirable. This study aimed to examine the variation in injection speeds in manual embryo transfer and pump-regulated embryo transfer (PRET). Seven laboratory technicians were asked to perform simulated transfers using the conventional embryo-transfer technique. Their injection speeds were compared with that of a PRET device. The results indicate that in manually performed transfers, even after standardization of the protocol, there is still a large variation in injection speed, while a PRET device generates a reliable and reproducible injection speed and therefore brings new possibilities for further standardization of the embryo-transfer procedure. Future research should reveal whether these experiments mimic real clinical circumstances and if a standardized injection speed results in more exact positioning of the transferred embryos and therefore higher pregnancy rates. The position of transfer air bubbles after embryo transfer is related to the pregnancy rate. With the currently used embryo-transfer technique, in which embryos are transferred manually with a syringe, we are not able to predict the final position of the air bubbles. This position depends on the injection speed of the syringe, which remains uncontrollable in embryo transfers that are performed manually even after standardization of the protocol. Therefore we developed an automated device that generates a reliable and reproducible injection speed, a pump-regulated embryo transfer (PRET) device. This study aimed to examine the variation in injection speeds in transfers performed manually and with the PRET device. Our results indicate that in manually performed transfers, even after standardization by protocol, there is still a large variation in injection speed and that the PRET device generates a reliable and reproducible injection speed and therefore brings new possibilities for further standardization of the embryo-transfer procedure. Future research should reveal whether our experiments mimic real clinical circumstances and if a standardized injection speed results in more exact positioning of the transferred embryos and therefore higher pregnancy rates.
机译:胚胎移植后移植气泡的位置与妊娠率有关。利用传统的手动胚胎移植技术,不可能预测气泡的最终位置。该位置主要取决于转移时的导管负载速度(注射速度),该参数即使在协议标准化后仍无法用常规技术控制。因此,期望开发一种产生标准化注射速度的自动化设备。这项研究旨在检查手动胚胎移植和泵调节胚胎移植(PRET)中注射速度的变化。要求七名实验室技术人员使用常规的胚胎移植技术进行模拟移植。将它们的注射速度与PRET设备的注射速度进行了比较。结果表明,在手动执行的转移中,即使在协议标准化之后,注射速度仍然存在较大差异,而PRET设备会产生可靠且可重复的注射速度,因此为进一步标准化胚胎转移带来了新的可能性程序。未来的研究应该揭示这些实验是否模仿真实的临床情况,以及标准化的注射速度是否能使移植胚胎的定位更加精确,从而提高妊娠率。胚胎移植后移植气泡的位置与妊娠率有关。使用当前使用的胚胎移植技术,即使用注射器手动移植胚胎,我们无法预测气泡的最终位置。此位置取决于注射器的注射速度,即使协议标准化后,手动进行的胚胎移植仍无法控制注射速度。因此,我们开发了一种可产生可靠且可再现的注射速度的自动化设备,即一种泵控式胚胎移植(PRET)设备。这项研究旨在检查手动和使用PRET设备进行的传输中注射速度的变化。我们的结果表明,即使按照协议进行了标准化,在手动执行的转移中,注射速度仍然存在较大差异,并且PRET设备产生了可靠且可重现的注射速度,因此为进一步标准化胚胎移植程序带来了新的可能性。未来的研究应揭示我们的实验是否模仿真实的临床情况,以及标准化的注射速度是否导致所转移胚胎的定位更加精确,从而提高妊娠率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号