We report the characterization of a recently introduced hybrid ionization source, matrix-assisted laser desorption electrospray ionization (MALDESI), coupled to a quadrupole Fourier transform ion cyclotron resonance mass spectrometry (QFT-ICR-MS) system. We first demonstrate the ability of MALDESI-QFT-ICR MS to directly analyze and provide high mass measurement accuracy (similar to 1 part-per-million) of a polypeptide using internal calibration. Second, we show the potential of MALDESI-QFT-ICR MS for the top-down characterization of multiply charged polypeptide cations. Finally, we demonstrate sub-femtomole detection limits in MALDESI-QFT-ICR MS using a combination of naturally occurring peptides and their respective stable isotope labeled forms. The results presented herein demonstrate the feasibility of several potential applications for MALDESI-QFT-CR MS for the direct analysis of intact biological molecules. Copyright (c) 2007 John Wiley & Sons, Ltd.
机译:我们报告了最近引入的混合电离源,基质辅助的激光解吸电喷雾电离(MALDESI)的表征,再加上四极傅里叶变换离子回旋共振质谱(QFT-ICR-MS)系统。我们首先证明了MALDESI-QFT-ICR MS使用内部校准可以直接分析多肽并提供高质量测量准确性(类似于百万分之一)的能力。其次,我们显示了MALDESI-QFT-ICR MS用于自上而下表征多电荷多肽阳离子的潜力。最后,我们结合天然存在的肽及其各自稳定的同位素标记形式,证明了在MALDESI-QFT-ICR MS中的亚飞沫检测限。本文介绍的结果证明了MALDESI-QFT-CR MS在直接分析完整生物分子方面的几种潜在应用的可行性。版权所有(c)2007 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号