Purpose: To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard. Materials and Methods: This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography. Results: Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively). Conclusion: Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography.
机译:目的:以低剂量计算机断层扫描(CT)为参考标准,评估腹部放射线照相在检测非法体内容器(以下称小包)中的诊断性能。材料和方法:本研究经机构伦理审查委员会批准,并获得知情同意。从2007年7月至2010年7月,有330人(296名男性,34名女性;平均年龄32岁[范围18-55岁])被怀疑接受了药包仰卧位腹部X光检查和小剂量CT检查。据报道腹部X线片有无小包,以低剂量CT作为参考标准。记录并分析低剂量CT上小包的密度和数量(≤12或> 12),以确定这些变量是否影响腹部X线摄影结果的解释。结果:在低剂量CT上检测到53位(16%)嫌疑犯中的数据包。腹部放射线照相对小包描绘的敏感性为0.77(53分之41),特异性为0.96(277分277)。在53例嫌疑人中,有16例(30%)在低剂量CT时,小包对肠内容物表现出同等衰减,结果为阳性。在低剂量CT结果呈阳性的53名嫌疑犯中,有19名(36%)的包裹少于12个。在低剂量CT处等衰减的包和少量的包(≤12)均与腹部X线检查的假阴性结果显着相关(分别为P = .004和P = .016)。结论:与低剂量CT相比,腹部X线摄影在筛查疑似携带药包的人群中的敏感性较低。小剂量CT是替代腹部X光片的有效成像方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号