首页> 外文期刊>Luminescence: The journal of biological and chemical luminescence >High-throughput method for the analysis of venlafaxine in pharmaceutical formulations and biological fluids, using a tris(2,2′-bipyridyl) ruthenium(II)-peroxydisulphate chemiluminescence system in a two-chip device
【24h】

High-throughput method for the analysis of venlafaxine in pharmaceutical formulations and biological fluids, using a tris(2,2′-bipyridyl) ruthenium(II)-peroxydisulphate chemiluminescence system in a two-chip device

机译:高通量方法,在两芯片设备中使用三(2,2'-联吡啶基)钌(II)-过氧二硫酸盐化学发光系统分析药物制剂和生物流体中的文拉法辛

获取原文
获取原文并翻译 | 示例
           

摘要

A simple, rapid and sensitive chemiluminescent (CL) method for the assay of venlafaxine (VEN) in pharmaceutical formulations and serum samples by a two-chip device is proposed. The method is based on the reaction of this drug with a tris(2,2′-bipyridyl) ruthenium(II)-peroxydisulphate CL system. The optimum chemical conditions for CL emission were investigated. The calibration graph was linear for the concentration range 0.02-8.0 μg/mL. The detection and quantification limits were found to be 0.006 and 0.018 μg/mL, respectively, while the relative standard deviation (RSD) was <2.0%. The present CL procedure was applied to the determination of VEN in pharmaceutical formulations and serum samples; the recovery levels were in the range 96.5-101.2%. The results suggest that the method is unaffected by the presence of common formulation excipients found in these samples.
机译:提出了一种简单,快速,灵敏的化学发光(CL)方法,可通过两芯片设备测定药物制剂和血清样品中的文拉法辛(VEN)。该方法基于该药物与三(2,2'-联吡啶基)钌(II)-过氧二硫酸盐CL体系的反应。研究了用于CL排放的最佳化学条件。浓度范围为0.02-8.0μg/ mL时,校准曲线为线性。检出限和定量限分别为0.006和0.018μg/ mL,而相对标准偏差(RSD)<2.0%。本CL方法适用于药物制剂和血清样品中VEN的测定。回收率在96.5-101.2%之间。结果表明该方法不受这些样品中常见配方赋形剂的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号