首页> 外文期刊>Catheterization and cardiovascular interventions: Official journal of the Society for Cardiac Angiography & Interventions >Catheter-based closure of atrial septal defects in the oval fossa with the Amplatzer device in patients in their first or second year of life.
【24h】

Catheter-based closure of atrial septal defects in the oval fossa with the Amplatzer device in patients in their first or second year of life.

机译:在第一或第二年患者中,使用Amplatzer装置基于导管的方法封闭卵圆窝的房间隔缺损。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To assess feasibility, safety, and efficacy of the use of Amplatzer occluders in closure of atrial septal defects (ASD) in children in the first 2 years of life. BACKGROUND: Although scattered reports on such closure have been published, no agreement consists on the policy. METHODS: In 654 patients of all ages, closure was achieved in 632 (96.6%). Data were analyzed retrospectively in all 71 children where an attempt had been made to close the ASD before their second birthday. RESULTS: Median age and body weight were 17.2 months (range 3.9-23.8) and 10.0 kg (range 3.8-14.5), respectively. Median fluoroscopy time was 13.6 min and median device size 15 mm. Successful closure was achieved in 68 children (95.8%). Three times the procedure was aborted: in one, the device repeatedly straddled the septum; in the other two, a small left atrium restricted the movement of the left-sided disc. One device embolized and was reimplanted after retrieval. One infant with multiple disorders died 6 days after closure from acute sepsis probably unrelated to the procedure. No other complications occurred. Only trivial shunts closing with time were registered during follow-up. Symptomatic patients profited markedly from closure. CONCLUSION: The results and complications of ASD closure with the Amplatzer device in patients in their first 2 years of life compare favorably with procedures in older patients, provided that the size of the septum and the dimensions in the left atrium are taken into consideration when selecting the size of the device.
机译:目的:评估使用Amplatzer封堵器封闭儿童出生后头两年的房间隔缺损(ASD)的可行性,安全性和有效性。背景:尽管已经发布了有关这种关闭的零星报告,但该政策并未达成任何协议。方法:在所有年龄段的654例患者中,有632例达到了结扎(96.6%)。回顾性分析了所有试图在第二个生日之前关闭自动进纸器的71名儿童的数据。结果:中位年龄和体重分别为17.2个月(范围3.9-23.8)和10.0千克(范围3.8-14.5)。透视的中位时间为13.6分钟,中位装置尺寸为15 mm。 68名儿童(95.8%)成功闭合。手术被中止了三次:一次,装置反复跨在隔垫上;在另外两个中,一个小的左心房限制了左侧椎间盘的运动。一种装置栓塞,取出后重新植入。一名患有多种疾病的婴儿死于急性败血症后6天死亡,可能与手术无关。没有其他并发症发生。在随访期间,仅记录了随时间关闭的琐碎分流器。有症状的患者从封堵中明显受益。结论:Amplatzer装置在其生命的最初2年内对ASD封闭的结果和并发症与老年患者的手术相比具有优势,前提是选择时要考虑隔垫的大小和左心房的大小设备的大小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号