首页> 外文期刊>Catheterization and cardiovascular interventions: Official journal of the Society for Cardiac Angiography & Interventions >Experimental evaluation of a new articulated Amplatzer ductal occluder device without fabric.
【24h】

Experimental evaluation of a new articulated Amplatzer ductal occluder device without fabric.

机译:一种新型无织物铰接式Amplatzer导管式封堵器的实验评估。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: To describe a new percutaneous PDA device. BACKGROUND: The ADO II was developed by AGA Medical for closure of small-moderate sized PDAs via a small delivery catheter from an antegrade or retrograde catheter approach. The objective of this study was to evaluate the technical feasibility, safety, and efficacy of the ADO II in a canine PDA model. METHODS: The ADO-II consists of multi-layer nitinol wire braid with symmetric retention disks and an articulating connecting center waist, without sewn-in polyester, that can be delivered though a 4-5F catheter. A PDA was surgically created in nine dogs. Transcatheter occlusion of the PDA was performed using the ADO II. Angiographic and hemodynamic data were obtained at 7, 30, 60, and 90 days post-procedure. The devices were then harvested for pathology. RESULTS: Devices were placed transarterially (n = 8) and transvenously (n = 1). All PDAs were occluded and there were no significant pressure gradients (P > 0.05) at the immediate and 90 post-implant evaluations. Pathology found endothelial coverage on all aortic and pulmonary disks, except at the tip of the microscrew. There were no procedural complications. One canine was euthanized 4 hr after device implant because of a clinical deterioration. The staff veterinarian and pathologist concluded that the animal's illness was not device related. CONCLUSIONS: The Amplatzer ADO II devices can be safely deployed in animal models of PDAs, with complete resolution of the PDA shunt. The lower profile and symmetry of the ADO II allows for venous or arterial approach and smaller delivery catheter size. The ADO-II is expected to be a preferred alternative for closure of small-moderate PDAs.
机译:目的:描述一种新的经皮PDA设备。背景:ADO II由AGA Medical开发,用于通过顺行或逆行导管方法通过小型输送导管闭合小中型PDA。这项研究的目的是评估犬PDA模型中ADO II的技术可行性,安全性和有效性。方法:ADO-II由多层镍钛合金丝编织物和对称的固定盘和一个铰接的连接中心腰组成,无需缝合聚酯,可以通过4-5F导管输送。通过手术在9只狗中创建了PDA。 PDA的经导管闭塞是使用ADO II进行的。术后7、30、60和90天获得血管造影和血液动力学数据。然后收获装置用于病理学。结果:设备经动脉(n = 8)和经静脉(n = 1)放置。所有PDA均被阻塞,并且在即刻和植入后90次评估时均无明显的压力梯度(P> 0.05)。病理发现除微螺钉尖端外,所有主动脉和肺盘均被内皮覆盖。没有手术并发症。由于临床恶化,一只狗在植入装置后4小时被安乐死。兽医和病理学家总结说,动物的疾病与设备无关。结论:Amplatzer ADO II设备可以安全地部署在PDA的动物模型中,并且具有PDA分流器的完整分辨率。 ADO II的低轮廓和对称性允许静脉或动脉入路,并且输送导管尺寸更小。 ADO-II有望成为封闭中小PDA的首选替代产品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号