首页> 外文期刊>Numerical Heat Transfer, Part A. Application: An International Journal of Computation and Methodology >Numerical study on some improvements in the passive cooling system of a radio base station
【24h】

Numerical study on some improvements in the passive cooling system of a radio base station

机译:无线电基站被动冷却系统某些改进的数值研究

获取原文
获取原文并翻译 | 示例
           

摘要

Passive cooling schemes, such as natural convection, are the most safe heat dissipation mode of electronic equipment. Some times the highest temperature of the PCB, rather than the highest of chips, is very much a concern due to technological reasons. In order to reduce the maximum PCB temperature, this article discusses various improvement methods via numerical simulation. These include optimization of fin number of heat sink, structure improvement of sun shield, and creation of insulation cavity in the base plate of heat sink. Taking the PCB of an RBS as an example, numerical simulation results show that by integrating these methods the maximum PCB temperature can be appreciably reduced. This article provides an example that by using a careful numerical thermal design, a passive cooling mode can sometimes meet the cooling requirement of a PCB with high power input in some extent.
机译:被动冷却方案,例如自然对流,是电子设备最安全的散热方式。有时由于技术原因,非常需要关注PCB的最高温度而不是芯片的最高温度。为了降低最高PCB温度,本文通过数值模拟讨论了各种改进方法。这些措施包括优化散热器的散热片数量,改进遮阳板的结构以及在散热器的底板中创建绝缘腔。以RBS的PCB为例,数值仿真结果表明,通过集成这些方法,可以最大程度地降低PCB的最高温度。本文提供了一个示例,通过使用仔细的数值热设计,被动冷却模式有时可以在某种程度上满足具有高功率输入的PCB的冷却要求。