THE HAZARD FROM A FIRE, over a hydrocarbon liquid (pool fire) or the burning of dispersed vapor mixed with air (vapor fire) to people and objects outside the fire, arises from heat radiated by the fire ("thermal radiation"). Different levels of hazards result depending upon the level of the incident radiant heat flux or intensity (indicated in units of kW/m2 or Btu/hr ft2), the area of exposure, the duration of exposure, and in the case of humans, the percent of body covered by clothing and the evasive actions taken. Hazard to people manifests in the form of skin burn or, in extreme cases, fatality. Wooden structures exhibit charring, ignition, or complete burning when subjected to high levels of thermal radiation flux.
机译:着火的危险是由火辐射产生的热量(“热辐射”)引起的,这种危险是由碳氢化合物液体引起的(池火)或与空气混合的分散蒸气燃烧(蒸气着火)而引起的。根据入射辐射热通量或强度(以kW / m2或Btu / hr ft2为单位),暴露的面积,暴露的持续时间,以及对于人类而言,会导致不同程度的危害。被衣服覆盖的身体百分比以及采取的回避行动。对人的危害表现为皮肤灼伤或在极端情况下可导致死亡。木质结构在经受高水平的热辐射通量时会出现炭化,着火或完全燃烧的现象。