The radial artery (RA) pressure waveform is commonly used to reconstruct the central aortic pressure waveform. Because the RA pressure waveform has been used as input to this process, its features that are dependent on the local arterial properties can influence the final reconstructed aortic waveform. In this study, we determined the effects of altered upper limb pulse wave velocity (PWV) and local wave reflection parameters on RA pressure waveform augmentation (RA-AIx). Twenty healthy volunteers (10 men) between the ages of 18 and 35 years of age were recruited. Simultaneous pressure waveforms were acquired using arterial tonometers from the right carotid and the radial arteries, prior to and following tourniquet induced hyperemia. The phase velocities from the pressure wave transfer function were used to estimate the pulse wave velocity (PWV_(oo) ), the local reflection coefficient (F) and an estimate of the terminal impedance of the upper limbs, PWV+__0+). The RA-AIx was represented as a linear, three-parameter model that included the input (the AIx of the carotid artery pressure waveform, CA-AIx), the T and PWV_(oo) of the arm. Tourniquet induced hyperemia did not alter T but reduced PWV_(oo) , and PWV+__0+) and increased RA-AIx. Multiple linear regression analysis indicated that RA-AIx was increased by high levels of CA-AIx and PWV_(oo) and decreased by elevated Y. The relative weighing of CA-AIx, T and PWV_(oo) on RA-AIx were 3:2:1, respectively. The AIx of RA is determined to an equal extent by the input and local factors. Interpretation of the AIx of the RA and the reconstructed central aortic waveform should be made in the context of this relationship.
机译:动脉(RA)压力波形通常用于重建中心主动脉压力波形。由于RA压力波形已被用作该过程的输入,因此其依赖于局部动脉特性的特征可能会影响最终重建的主动脉波形。在这项研究中,我们确定了改变的上肢脉搏波速度(PWV)和局部波反射参数对RA压力波形增强(RA-AIx)的影响。招募了20名年龄在18至35岁之间的健康志愿者(10名男性)。在止血带引起的充血之前和之后,使用动脉眼压计从右颈动脉和ton动脉获取同时的压力波形。来自压力波传递函数的相速度用于估计脉搏波速度(PWV_(oo)),局部反射系数(F)以及上肢的末端阻抗估计(PWV + __ 0+)。 RA-AIx表示为线性三参数模型,其中包括输入(手臂的颈动脉压力波形的AIx,CA-AIx),T和PWV_(oo)。止血带引起的充血并没有改变T,而是降低了PWV_(oo)和PWV + __ 0+)并增加了RA-AIx。多元线性回归分析表明,高水平的CA-AIx和PWV_(oo)使RA-AIx增加,而Y升高则RA-AIx降低。RA-AIx上CA-AIx,T和PWV_(oo)的相对权重为3:分别为2:1。 RA的AIx由输入和局部因素在同等程度上确定。在这种关系的背景下,应该对RA的AIx和重建的中心主动脉波形进行解释。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号