首页> 外文期刊>Neurosurgery >New technique for application of fibrin sealant: rubbing method devised to prevent cerebrospinal fluid leakage from dura mater sites repaired with expanded polytetrafluoroethylene surgical membranes.
【24h】

New technique for application of fibrin sealant: rubbing method devised to prevent cerebrospinal fluid leakage from dura mater sites repaired with expanded polytetrafluoroethylene surgical membranes.

机译:纤维蛋白封闭剂应用的新技术:设计了摩擦方法,以防止脑脊液从扩展的聚四氟乙烯外科手术膜修复的硬脑膜部位漏出。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The effectiveness of a strong, pressure-tight method for fibrin sealant application was experimentally and clinically evaluated, using expanded polytetrafluoroethylene (ePTFE) surgical membranes. METHODS: Two application methods were examined in two groups. For Group 1, 1 ml each of Solutions A and B was simply sprayed over the surface (spray method). For Group 2, a small amount of Solution A was rubbed into the sutured site and then Solutions A and B were sprayed over the surface (rubbing method). In the experimental study, a moment pressure elevation test and a continuous stepwise pressure elevation test were performed for both groups. The clinical study was conducted using 350 patients undergoing craniotomies. The ePTFE surgical membrane was used for 180 patients but not the other 170 patients. RESULTS: In the experimental study, the bursting pressures were 51.4 +/- 13.0 cm H2O for Group 1 and 129 +/- 35.0 cm H2O for Group 2 in the moment pressure elevation test and 27.0 +/- 6.7 cm H2O and 100 +/- 31.9 cm H2O, respectively, in the continuous stepwise pressure elevation test. The sealing effect was significantly greater for Group 2 than for Group 1 in both tests (P < 0.001). In the clinical study using ePTFE surgical membranes, the rubbing method significantly reduced the incidence of postoperative cerebrospinal fluid leakage (1.4%), compared with the spray method (18.3%), when external decompression was not concomitantly used (P < 0.01). CONCLUSION: The sealing effect of fibrin sealant on cerebrospinal fluid leakage was significantly greater with the rubbing method than with the spray method. The strong sealing effect obtained with the rubbing method is thought to result from firm linkage between the ePTFE surgical membrane and the fibrin sealant and also from fibrin being formed even in needle holes and spaces in the sutured site.
机译:目的:使用膨胀的聚四氟乙烯(ePTFE)外科手术膜,通过实验和临床评估了一种牢固,耐压的方法对纤维蛋白密封剂的应用效果。方法:将两种施用方法分为两组。对于第1组,将溶液A和B分别分别喷雾1毫升到表面上(喷雾法)。对于第2组,将少量溶液A摩擦到缝合部位,然后将溶液A和B喷涂在表面上(摩擦法)。在实验研究中,两组均进行了矩压力升高测试和连续逐步压力升高测试。该临床研究是针对350例接受开颅手术的患者进行的。 ePTFE手术膜用于180例患者,而其他170例则不使用。结果:在实验研究中,在瞬间压力升高试验中,第1组的破裂压力为51.4 +/- 13.0 cm H2O,第2组的破裂压力为129 +/- 35.0 cm H2O,27.0 +/- 6.7 cm H2O和100 + / -在连续的逐步压力升高测试中分别为31.9 cm H2O。在两个试验中,第2组的密封效果均显着大于第1组(P <0.001)。在不使用外部减压的情况下,使用ePTFE外科手术膜的临床研究中,与喷雾法(18.3%)相比,摩擦法显着降低了术后脑脊液漏的发生率(1.4%)(P <0.01)。结论:纤维蛋白密封剂对脑脊液渗漏的密封作用与摩擦法相比明显优于喷雾法。认为通过摩擦法获得的强密封效果是由于ePTFE手术膜和血纤蛋白密封剂之间的牢固连接,也是由于即使在缝合部位的针孔和空间中也形成了血纤蛋白。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号