首页> 外文期刊>NeuroImage >Standardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T.
【24h】

Standardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T.

机译:多中心研究中的标准化结构磁共振成像,使用1.5 T下的定量T1和T2成像。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The ability to acquire MRI data with consistent tissue contrast at multiple time points, and/or across different imaging centres has become increasingly important as the number of large longitudinal and multicentre studies has grown. Here, the use of quantitative magnetic resonance relaxation times measurement, or, voxel-wise determination of the intrinsic longitudinal and transverse relaxation times, T1 and T2 respectively, for standardizing the structural imaging component of such studies is reported. To demonstrate the ability to standardize across multiple time-points and imaging centres, T1 and T2 maps of seven healthy volunteers were acquired using the rapid DESPOT1 and DESPOT2 (driven equilibrium single pulse observation of T1 and T2) mapping techniques at three centres across the United Kingdom (each centre utilizing scanners from competing manufacturers and/or with varying gradient performance). An average coefficient of variation of the estimates of T1 and T2 was found to be approximately 6.5% and 8%, respectively, across the three centres and comparable to that achieved between repeated imaging sessions performed at the same centre. With a total combined imaging time of less than 12 min for whole-brain approximately 1.2 mm isotropic voxel T1 and T2 maps, quantitative voxel-wise T1 and T2 mapping represents an attractive and easy-to-implement approach for signal intensity standardization and normalization. Further, as T1 and T2 are related to tissue microstructure and biochemistry, quantitative images provide additional diagnostic information that can be compared between patient and control populations, for example through voxel-based analysis techniques.
机译:随着大型纵向和多中心研究数量的增加,在多个时间点和/或在不同成像中心获取具有一致组织对比度的MRI数据的能力变得越来越重要。在此,报道了使用定量的磁共振弛豫时间测量或固有纵向和横向弛豫时间T1和T2的体素确定来标准化此类研究的结构成像组件。为了展示跨多个时间点和成像中心进行标准化的能力,在美国境内的三个中心使用快速DESPOT1和DESPOT2(对T1和T2进行驱动平衡单脉冲观测)制图技术获得了7名健康志愿者的T1和T2图王国(每个中心都使用来自竞争制造商的扫描仪和/或具有不同梯度性能的扫描仪)。发现三个中心的T1和T2估计值的平均变异系数分别约为6.5%和8%,这与在同一中心进行的多次成像之间的可比性相当。全脑约1.2毫米各向同性体素T1和T2映射的总合并成像时间少于12分钟,定量体素方向T1和T2映射代表了一种有吸引力且易于实现的信号强度标准化和归一化方法。此外,由于T1和T2与组织的微结构和生物化学有关,定量图像提供了附加的诊断信息,可以通过基于体素的分析技术在患者和对照人群之间进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号