首页> 外文期刊>Cardiovascular and Interventional Radiology: A Journal of Imaging in Diagnosis and Treatment >Renal artery embolization combined with radiofrequency ablation in a porcine kidney model: effect of small and narrowly calibrated microparticles as embolization material on coagulation diameter, volume, and shape.
【24h】

Renal artery embolization combined with radiofrequency ablation in a porcine kidney model: effect of small and narrowly calibrated microparticles as embolization material on coagulation diameter, volume, and shape.

机译:猪肾脏模型中的肾动脉栓塞术与射频消融相结合:小的狭窄校准微粒作为栓塞材料对凝血直径,体积和形状的影响。

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume_segmented, and volume_calculated were determined to describe the size of the RFAs. To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 +/- 3.6 vs. 17.2 +/- 1.8 mm; p < 0.001) and width (20.1 +/- 2.9 vs. 12.6 +/- 3.7 mm; p < 0.001); significantly larger volume_segmented (8.6 +/- 3.2 vs. 3.0 +/- 0.7 ml; p < 0.001) and volume_calculated (8.4 +/- 3.0 ml vs. 3.3 +/- 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 +/- 0.10 vs. 1.48 +/- 0.44; p < 0.05), sphericity (1.55 +/- 0.44 vs. 1.96 +/- 0.43; p < 0.01), and eccentricity (0.84 +/- 0.61 vs. 1.73 +/- 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 +/- 0.14 vs. 0.45 +/- 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.
机译:这项研究的目的是评估狭窄和狭窄校准的微粒对肾动脉的栓塞对猪肾脏的凝血直径,体积和射频消融(RFA)形状的影响。在12头猪的24个肾脏中进行了48次RFA。在6只动物中,用狭窄的小颗粒进行了双侧肾动脉栓塞术。使用相同的系统参数消融上,下肾两极。应用三维分割软件,将RFA分割在已注册的2毫米薄的宏观切片上。确定长度,深度,宽度,分割的体积和计算的体积以描述RFA的大小。为了评估RFA的形状,深度与宽度之比(完美的对称与病变的长度以1的比率表示),球形度(完美的球体以1的球形度比率表示),偏心率(完美的球体偏心度为0表示圆形,并确定圆度(以1表示圆形)。与未栓塞的RFA相比,栓塞后的深度(23.4 +/- 3.6 vs. 17.2 +/- 1.8 mm; p <0.001)和宽度(20.1 +/- 2.9 vs. 12.6 +/- 3.7 mm; p <0.001)明显更大。明显更大的体积分段(8.6 +/- 3.2 vs. 3.0 +/- 0.7 ml; p <0.001)和体积计算的(8.4 +/- 3.0 ml vs. 3.3 +/- 1.1 ml; p <0.001);深宽比(1.17 +/- 0.10 vs. 1.48 +/- 0.44; p <0.05),球形度(1.55 +/- 0.44 vs. 1.96 +/- 0.43; p <0.01)和偏心率(0.84)明显更低+/- 0.61比1.73 +/- 0.91; p <0.01)比率;圆度明显更高(0.62 +/- 0.14与0.45 +/- 0.16; p <0.01)。肾小动脉狭窄狭窄校准的动脉栓塞会影响猪肾脏中RFA的凝血直径,体积和形状。与未栓塞的RFA相比,栓塞的RFA显着更大且更球形。

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号