首页> 外文期刊>Neurological Research: An Interdisciplinary Quarterly Journal >Improved diagnostic value of a TCD-based non-invasive ICP measurement method compared with the sonographic ONSD method for detecting elevated intracranial pressure
【24h】

Improved diagnostic value of a TCD-based non-invasive ICP measurement method compared with the sonographic ONSD method for detecting elevated intracranial pressure

机译:与基于超声的ONSD方法相比,基于TCD的无创ICP测量方法对颅内压升高的诊断价值更高

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: To compare the diagnostic reliability of optic nerve sheath diameter (ONSD) ultrasonography with a transcranial Doppler (TCD)-based absolute intracranial pressure (ICP) value measurement method for detection of elevated ICP in neurological patients. The ONSD method has been only tested previously on neurosurgical patients. Methods: A prospective clinical study of a non-invasive ICP estimation method based on ONSD correlation with ICP and an absolute ICP value measurement method based on a two-depth TCD technology has recruited 108 neurological patients. Ninety-two of these patients have been enrolled in the final analysis of the diagnostic reliability of ONSD ultrasonography and 85 patients using the absolute ICP value measurement method. All non-invasive ICP measurements were compared with 'Gold Standard' invasive cerebrospinal fluid (CSF) pressure measurements obtained by lumbar puncture. Receiver-operating characteristic (ROC) analysis has been used to investigate the diagnostic value of these two methods. Results: The diagnostic sensitivity, specificity, and the area under the ROC curve (AUC) of the ONSD method for detecting elevated intracranial pressure (ICP >14.7 mmHg) were calculated using a cutoff point of ONSD at 5.0 mm and found to be 37.0%, 58.5%, and 0.57, respectively. The diagnostic sensitivity, specificity, and AUC for the non-invasive absolute ICP measurement method were calculated at the same ICP cutoff point of 14.7 mmHg and were determined to be 68.0%, 84.3%, and 0.87, respectively. Conclusions: The non-invasive ICP measurement method based on two-depth TCD technology has a better diagnostic reliability on neurological patients than the ONSD method when expressed by the sensitivity and specificity for detecting elevated ICP >14.7 mmHg.
机译:目的:比较基于神经多普勒(TCD)的绝对颅内压(ICP)值测量方法对视神经鞘管径(ONSD)超声检查在神经系统疾病患者中ICP升高的诊断可靠性。 ONSD方法之前仅在神经外科患者中进行过测试。方法:前瞻性临床研究基于ONSD与ICP的相关性的无创ICP估计方法以及基于两深度TCD技术的绝对ICP值测量方法,招募了108名神经病患者。使用绝对ICP值测量方法对其中的92名患者进行了ONSD超声检查诊断可靠性的最终分析,对85名患者进行了分析。将所有非侵入性ICP测量值与通过腰穿术获得的“金标准”侵入性脑脊液(CSF)压力测量值进行比较。接收者操作特征(ROC)分析已用于研究这两种方法的诊断价值。结果:使用ONSD的临界点(5.0毫米)计算出ONSD检测颅内压升高(ICP> 14.7 mmHg)的方法的诊断敏感性,特异性和ROC曲线下面积(AUC),发现为37.0% ,58.5%和0.57。在相同的ICP临界点14.7 mmHg下计算出非侵入式绝对ICP测量方法的诊断灵敏度,特异性和AUC,分别确定为68.0%,84.3%和0.87。结论:基于检测深度ICP> 14.7 mmHg的敏感性和特异性,基于两深度TCD技术的无创ICP测量方法对神经病患者的诊断可靠性优于ONSD方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号