INTRODUCTION: Our aim was to examine the feasibility of a computed tomographic angiography (CTA) protocol using a reduced dose of high-concentration contrast material on a 16 multidetector-row system to visualize both cervical and cerebral arteries in one session. METHODS: In 31 consecutive patients, we performed CTA covering the cervical and cerebral arteries. The patients were assigned to one of three groups: group A, 100 mL of 300 mgI/mL; group B, 80 mL of 370 mgI/mL; and group C, 60 mL of 370 mgI/mL followed by a 30-mL saline flush. Arterial enhancements were quantified by measuring attenuation values of the common carotid artery, internal jugular vein, proximal middle cerebral artery (MCA), basilar artery, and straight sinus on source images. Visualizations of the carotid bifurcation and arteries continuing to the circle of Willis were rated on a three-point grading scale on CTA images for qualitative assessment. RESULTS: There were no statistically significant differences in attenuation of all the target vessels among the three groups, with the one exception being a lower attenuation of the MCA in group C than in groups A and B (P < 0.01). Neither were there any significant differences noted among the three groups on the visual assessment. CONCLUSION: Use of a reduced dose of high iodine concentration contrast material may provide an equal degree of image quality for CTA covering the craniocervical region on a 16 multidetector-row system.
机译:简介:我们的目的是研究在16个多探测器行系统上使用减少剂量的高浓度造影剂在一次会议中可视化颈动脉和脑动脉的计算机断层血管造影(CTA)方案的可行性。方法:在连续31例患者中,我们进行了覆盖颈和脑动脉的CTA。将患者分为三组之一:A组,100 mL 300 mgI / mL; B组:80 mL,370 mgI / mL; C组:60 mL 370 mgI / mL,然后用30 mL盐水冲洗。通过在源图像上测量颈总动脉,颈内静脉,近端中脑动脉(MCA),基底动脉和直窦的衰减值来量化动脉增强。在CTA图像上以三点分级量表对继续延伸至Willis圆的颈动脉分叉和动脉的可视化进行定性评估。结果:三组中所有目标血管的衰减均无统计学意义,唯一的例外是C组的MCA衰减低于A组和B组(P <0.01)。视觉评估的三组之间均未发现任何显着差异。结论:使用减少剂量的高碘浓度造影剂可以为CTA覆盖16排多排探测器系统的颅颈区域提供同等程度的图像质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号