首页> 外文期刊>Nuclear engineering and design >Comparison of calculated and measured spent nuclear fuel decay heat with CASMO5, SNF and standard methods
【24h】

Comparison of calculated and measured spent nuclear fuel decay heat with CASMO5, SNF and standard methods

机译:

获取原文
获取原文并翻译 | 示例
           

摘要

? 2023 The Author(s)In this paper, we present a comparison between measured and calculated decay values for spent nuclear fuel assemblies from the Clab, GE-Morris EMAD facilities. Two codes are applied: CASMO5 and SNF, using different nuclear data libraries (JEF-2.2, JEFF-3.1.1, JEFF-3.2, ENDF/B-VII.1 and ENDF/B-VIII.0) and different code versions. Additionally values from four standard and guides for calculation of decay heats (ANS 2014, DIN 2014, ISO 2022 and RG-3.54 2018) were also compared with the measurements. All simulations with different codes, code versions and methods are based on the same geometry and irradiation descriptions for a single assembly, providing more convenient comparisons of results. The impact of nuclear data libraries and computational methods are shown, compared to the spread of C/E (Calculations over Experiment) values between the 256 considered measurements. Finally, a comparison of the most important nuclides contributing to the decay heat is presented between measured assemblies and more recent cases corresponding to higher burnup, initial enrichment and longer cooling times.