INTRODUCTION: Urine diagnosis by light microscopy is considerably more difficult when specimens are analyzed after a certain period of time. OBJECTIVES: (1) To investigate whether this change effectively exists at a significant level of 12 h. (2) To apply measures, once the above has been done, allowing for the analysis of samples beyond 12 h in similar conditions. MATERIALS AND METHODS: Both freshly produced urine and pathological samples were used under certain experimental conditions: initial, 12 h, 12 h + fridge at 4 degrees C (F), 12 h + chemical preservation (S) and 12 h + SF. The chemical preservative was prepared at a 50/50 ratio with 3% formaldehyde and 2.5% glutaraldehyde by the addition of a buffer of pH 7.2-7.4, resulting in a solution of pH 7.35 at 25 degrees C room temperature. Urinalysis was carried out on all samples: glucose (enzymatic method of hexokinase) and total protein in liquid (red pyrogallol method). Centrifugation was followed by sediment analysis with light microscopy. Statistical analysis was done with the Kolmogorov-Smirnov normality test, Friedman nonparametric test and multiple comparisons. RESULTS AND CONCLUSION: Urine samples tested 12 h after having been produced changed significantly (p<0.0001), making it necessary to adopt certain measures to maintain their initial conditions. In our case, after the addition of the chemical preservative, samples did not present any changes (p>0.10) in relation to the initial conditions and were seen to be reliable, therefore indicating the suitability and effectiveness of the analytical conditions (urinalysis in particular, sediment analysis).
机译:简介:在一定时间后对标本进行分析时,通过光学显微镜对尿液进行诊断非常困难。目的:(1)研究这种变化是否在12 h的显着水平上有效存在。 (2)一旦采取了上述措施,应采取措施,允许在类似条件下分析超过12小时的样品。材料与方法:在某些实验条件下使用新鲜产生的尿液和病理学样品:初始,12 h,12 h +冰箱在4摄氏度(F),12 h +化学保存(S)和12 h + SF。通过添加pH 7.2-7.4的缓冲液,以50/50的比例与3%的甲醛和2.5%的戊二醛制备化学防腐剂,在25℃的室温下得到pH 7.35的溶液。对所有样品进行尿液分析:葡萄糖(己糖激酶的酶法)和液体中的总蛋白(红色邻苯三酚法)。离心后,用光学显微镜进行沉积物分析。使用Kolmogorov-Smirnov正态性检验,Friedman非参数检验和多重比较进行统计分析。结果与结论:尿液样本在生产后12小时内发生了显着变化(p <0.0001),因此有必要采取某些措施来维持其初始状态。在我们的情况下,添加化学防腐剂后,样品相对于初始条件没有任何变化(p> 0.10),并且被认为是可靠的,因此表明了分析条件的适用性和有效性(尤其是尿液分析) ,沉积物分析)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号