In this paper, we summarize some results of our ab initio simulations aimed at investigating the mechanism of the NC-AFM image contrast on semiconductor and metallic surfaces. We start with an introduction into the basic ideas behind the ab initio simulation process of the NC-AFM experimental results. Our simulations reveal that the interaction of a clean silicon tip with a semiconductor surface like InAs(110) might lead to bond-formation and bond-breaking processes during the approach and retraction of the tip. This imaging mechanism is very similar to that observed on a metallic surface like Ag(110). Interestingly, a clean silicon tip can become contaminated with Ag surface atoms. On both types of surface we observe a significant energy dissipation which is caused by a hysteresis in the tip–sample force curves calculated on the approach and retraction path.
机译:在本文中,我们总结了一些从头开始的仿真结果,旨在研究半导体和金属表面上NC-AFM图像对比度的机理。我们首先介绍NC-AFM实验结果从头开始仿真过程背后的基本思想。我们的仿真表明,清洁的硅尖端与半导体表面(如InAs(110))的相互作用可能会导致尖端接近和缩回过程中的键形成和键断裂过程。这种成像机制与在类似于Ag(110)的金属表面上观察到的成像机制非常相似。有趣的是,干净的硅尖端可能会被Ag表面原子污染。在两种类型的表面上,我们都观察到了明显的能量耗散,这是由进近和回退路径上计算出的针尖-力曲线中的磁滞引起的。