首页> 外文期刊>Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA >Three-dimensional in vivo motion analysis of normal knees employing transepicondylar axis as an evaluation parameter
【24h】

Three-dimensional in vivo motion analysis of normal knees employing transepicondylar axis as an evaluation parameter

机译:跨icon轴作为评估参数的正常膝盖的三维体内运动分析

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: The transepicondylar axis (TEA) has been used as a flexion axis of the knee and a reference of the rotational alignment of the femoral component. However, no study has showed dynamic normal knee kinematics employing TEA as the evaluation parameter throughout the full range of motion in vivo. The purpose of this study was to analyze dynamic kinematics of the normal knee through the full range of motion via the 3-dimensional to 2-dimensional registration technique employing TEA as the evaluation parameter. Methods: Dynamic motion of the right knee was analyzed in 20 healthy volunteers (10 female, 10 male; mean age 37.2 years). Knee motion was observed as subjects squatted from standing with knee fully extended to maximum flexion. The following parameters were determined: (1) Anteroposterior translations of the medial and lateral ends of the TEA; and (2) changes in the angle of the TEA on the tibial axial plane (rotation angle). Results: The medial end of the TEA demonstrated anterior translation (3.6 ± 3.0 mm) from full extension to 30° flexion and demonstrated posterior translation (18.1 ± 3.7 mm) after 30°, while the lateral end of the TEA demonstrated consistent posterior translation (31.1 ± 7.3 mm) throughout knee flexion. All subjects exhibited femoral external rotation (16.9 ± 6.2°) relative to the tibia throughout knee flexion. Conclusion: Compared to previously used parameters, the TEA showed bicondylar posterior translation from early flexion phase. These results provide control data for dynamic kinematic analyses of pathologic knees in the future and will be useful in the design of total knee prostheses.
机译:目的:经上icon轴(TEA)已用作膝盖的屈曲轴和股骨组件旋转对齐的参考。但是,尚无研究显示在整个运动过程中,采用TEA作为评估参数的动态正常膝关节运动学。这项研究的目的是通过使用TEA作为评估参数的3维到2维配准技术来分析正常膝盖在整个运动范围内的动态运动学。方法:分析了20名健康志愿者(其中10名女性,10名男性;平均年龄37.2岁)的右膝动态运动。当受试者站立时蹲下,膝盖完全伸展至最大屈曲时,观察到膝盖运动。确定以下参数:(1)TEA内侧和外侧末端的前后平移; (2)TEA在胫骨轴向平面上的角度(旋转角度)的变化。结果:TEA的内侧端显示从完全伸展到30°屈曲的前移(3.6±3.0 mm),并在30°后显示后移(18.1±3.7 mm),而TEA的外侧端显示一致的后移( 31.1±7.3毫米)。所有受试者在整个膝关节屈曲过程中均表现出相对于胫骨的股骨外旋(16.9±6.2°)。结论:与先前使用的参数相比,TEA显示了早期屈曲期的双con后移。这些结果为将来对病理性膝关节进行动态运动学分析提供了控制数据,将对全膝关节假体的设计有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号