首页> 外文期刊>Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA >Reliability of lower extremity alignment measurement using radiographs and PACS.
【24h】

Reliability of lower extremity alignment measurement using radiographs and PACS.

机译:使用射线照片和PACS进行下肢对中测量的可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Lower extremity alignment is an important consideration prior to cartilage surgery and/or osteotomy about the knee. This is measured on full length standing hip to ankle radiographs, which has traditionally been done using hard copy radiographs. However, the advent of PACS (Picture Archiving and Communication Systems) has allowed these measurements to be done on computer based digital radiographs. The objectives of this study were to evaluate the intra- and inter-observer reliability of lower limb alignment measures manually obtained from hard copy radiographs versus using the Philips Easy Vision system, and to assess the subjective ease of use for the two methods. METHODS: Forty-two patients who underwent surgery and who had a standing hip to ankle radiograph on file were identified. Four raters, including two radiologists and two orthopaedic surgeons, measured each hard copy radiograph and computer image on two separate occasions. Three measurements were recorded for each hard copy radiograph and computer image-width of tibial plateau, the distance from the medial aspect of the tibial plateau to the weight-bearing line, and the mechanical axis. RESULTS: All correlations for this study were high. For tibial plateau data, the hard copy radiographs compared to PACS demonstrated intra-class correlation coefficients (ICC) ranging from 0.93 to 0.99 for inter-rater reliability for the four raters. The ICC for intra-rater reliability for hard copies ranged from 0.90 to 0.99 and for PACS from 0.94 to 0.99. The inter-rater data comparing raters ranged from 0.87 to 0.98 for hard copy radiographs and from 0.98 to 0.99 for PACS. For mechanical axis data, the ICC for hard copy radiograph compared to PACS ranged from 0.93 to 0.97 for the intra-rater reliability for the four raters. The intra-rater reliability for mechanical axis data on hard copy radiograph ranged from an ICC of 0.86 to 0.96, and for PACS the ICC ranged from 0.93 to 0.99. The inter-observer data for hard copy radiographs using the mechanical axis ranged from 0.88 to 0.94 and for PACS ranged from 0.93 to 0.97. The physicians rated PACS as statistically significantly easier to use when compared to hard copy (P = 0.03). CONCLUSION: Evaluation of lower extremity alignment using two techniques prior to knee surgery was found to have higher inter- and intra-observer reliability using PACS software. PACS is now used prior to cartilage surgery and/or osteotomy to measure both alignment and the location of the weight bearing line on the tibial plateau both before and after surgery. LEVEL OF EVIDENCE: Diagnostic study, Level I.
机译:目的:下肢对准是在进行软骨手术和/或膝盖切骨术之前的重要考虑因素。这是在全长站立的臀部到踝部X射线照片上测量的,传统上是使用硬拷贝X射线照片完成的。但是,PACS(图片存档和通信系统)的出现使这些测量可以在基于计算机的数字X射线照片上进行。这项研究的目的是评估从硬拷贝X射线照相术与使用Philips Easy Vision系统手动获得的下肢对准措施在观察者内和观察者之间的可靠性,并评估这两种方法的主观易用性。方法:确定了42例接受了手术治疗并记录了臀部到踝关节X线照片的患者。包括两名放射科医生和两名整形外科医生在内的四个评估者分别在两个不同的场合测量了每个硬拷贝射线照相和计算机图像。记录每个硬拷贝射线照相和胫骨平台的计算机图像宽度,从胫骨平台的内侧到承重线的距离以及机械轴的三个测量值。结果:这项研究的所有相关性都很高。对于胫骨平台数据,与PACS相比,硬片X线照片显示四个评估者之间的评估者间可靠性的类内相关系数(ICC)为0.93至0.99。硬拷贝的评估者内部可靠性的ICC为0.90至0.99,而PACS的ICC为0.94至0.99。对于硬拷贝X射线照片,评估者间数据比较评估者的范围为0.87至0.98,对于PACS,评估者之间的数据评估者的范围为0.98至0.99。对于机械轴数据,四个评估者的内部评估者可靠性,与PACS相比,硬拷贝X线照片的ICC为0.93至0.97。硬拷贝X射线照片上机械轴数据的评定者内部可靠性范围从0.86到0.96,而PACS的ICC范围从0.93到0.99。使用机械轴的硬拷贝射线照片的观察者间数据范围为0.88至0.94,而PACS的观察者间数据范围为0.93至0.97。与硬拷贝相比,医师对PACS的统计上明显更易于使用(P = 0.03)。结论:使用PACS软件在膝关节手术之前使用两种技术评估下肢对中性具有较高的观察者间和观察者内可靠性。现在,PACS在进行软骨手术和/或截骨术之前用于在手术前后都测量胫骨平台上承重线的对齐方式和位置。证据级别:诊断研究,I级。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号