To determine the optimal recording site for phrenic nerve conduction studies, six different recording techniques were compared in 11 healthy volunteers (22 phrenic nerves). The mean diaphragm compound muscle action potential (CMAP) amplitude, side-to-side difference, and the number of studies with a false-positive result (CMAP amplitude <0.30 mV) were compared for each technique. The largest amplitude (0.65 +/- 0.23 mV, range 0.30-1.2 mV) with good right-left agreement (mean difference 0.15 mV) and no false positives was obtained using technique 1, where the G1 electrode was positioned 5 cm above the xiphoid process and G2 16 cm from G1 along the costal margin. This was also the easiest technique to perform. It does not require rib counting, which may be difficult and inaccurate, especially in overweight patients. At least one false positive occurred with each of the remaining five techniques.
机译:为了确定神经传导研究的最佳记录部位,在11名健康志愿者(22神经)中比较了六种不同的记录技术。比较了每种技术的平均横compound膜复​​合肌肉动作电位(CMAP)幅度,左右差异以及具有假阳性结果的研究数量(CMAP幅度<0.30 mV)。使用技术1获得最大振幅(0.65 +/- 0.23 mV,范围0.30-1.2 mV),具有良好的左右一致性(平均差0.15 mV)且没有假阳性,其中G1电极位于剑突上方5 cm过程和G2沿肋缘距G1 16厘米。这也是最容易执行的技术。它不需要肋骨计数,这可能是困难且不准确的,尤其是在超重患者中。其余五种技术中的每一种都至少发生一个假阳性。