The effect of the position of an edge filter within a ratiometric wavelength measurement system was investigated based on three cases: (1) the reflected fibre Bragg grating (FBG) signal passes through both the reference arm and the edge filter arm, (2) the reflected FBG signal is connected directly to the edge filter arm and does not pass through the reference arm, (3) the edge filter sits in line with the FBG and thus the source power is filtered prior to reaching the FBG. Both numerical simulations and experimental results show that cases 1 and 2 have similar system performance whilst case 3 is the best arrangement which offers the highest wavelength resolution.
机译:在以下三种情况下,研究了比率式波长测量系统中边缘滤波器的位置影响:(1)反射光纤布拉格光栅(FBG)信号同时通过参考臂和边缘滤波器臂,(2)反射的FBG信号直接连接到边缘滤波器臂,并且不通过参考臂,(3)边缘滤波器与FBG对准,因此在到达FBG之前先对源功率进行滤波。数值模拟和实验结果均表明,情况1和2具有相似的系统性能,而情况3是提供最高波长分辨率的最佳布置。