首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >Determination of manganese and zinc in powdered chocolate samples by slurry sampling using sequential multi-element flame atomic absorption spectormetry
【24h】

Determination of manganese and zinc in powdered chocolate samples by slurry sampling using sequential multi-element flame atomic absorption spectormetry

机译:连续多元素火焰原子吸收光谱法通过浆液采样法测定巧克力粉样品中的锰和锌

获取原文
获取原文并翻译 | 示例
           

摘要

In the present work, a slurry sampling flame atomic absorption spectrometric method to determine directly manganese and zinc in powdered chocolate samples is proposed. The optimization step was performed using univariate methodology involving the following factors: nature and concentration of the acid solution, sonication time, and particle size. The established conditions led to the use of a sample mass of 150 mg, 2.0 mol L-1 nitric acid solution, sonication time of 15 min, and a slurry volume of 50 mL. This method allows the determination of manganese and zinc with detection limit of 52 and 61 ng g(-1), respectively, and a precision expressed as relative standard deviation (RSD) of 2.6% and 3.2% (both, n = 10) for contents of manganese and zinc of 52.4 and 100.0 mu g g(-1), respectively. The proposed method was applied for determination of manganese and zinc in five powdered chocolate samples. In these, the manganese content varied from 42.8 to 52.7 and from 88.6 to 102.4 mu g g(-1) of zinc. The analytical results were compared with the results obtained by analysis of these samples after digestion using open vessel and acid bomb digestion procedures and determination using FS-FAAS. The statistical comparison by t-test (95% confidence level) showed no significant difference between these results. (c) 2006 Elsevier B.V. All rights reserved.
机译:在目前的工作中,提出了一种通过浆液采样火焰原子吸收光谱法直接测定巧克力粉样品中锰和锌的方法。使用涉及以下因素的单变量方法进行优化步骤:酸溶液的性质和浓度,超声处理时间和粒径。建立的条件导致使用150 mg的样品质量,2.0 mol L-1硝酸溶液,15分钟的超声处理时间和50 mL的浆料体积。该方法可以测定锰和锌,检出限分别为52和61 ng g(-1),精密度表示为相对标准偏差(RSD)分别为2.6%和3.2%(n = 10)。锰和锌的含量分别为52.4和100.0 mu gg(-1)。该方法用于测定五个巧克力粉样品中的锰和锌。其中锌的锰含量从42.8至52.7和88.6至102.4μg g(-1)不等。将分析结果与通过使用敞口容器和酸弹消解程序进行消解并通过FS-FAAS测定后对这些样品进行分析所获得的结果进行比较。通过t检验进行的统计比较(95%置信水平)显示这些结果之间没有显着差异。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号