In this paper, we report our experimental design in searching a smart and easy-to-read dosimeter used to detect 6MV X-rays for improving patient safety in radiation oncology. The device was based on an organic emissive solutions of poly(2-methoxy-5(2'-ethylhexyloxy)-p-phenylenevinylene) (MEH-PPV), aluminum-tris-(8-hydroxyquinoline) (Alq3) and additive components which were characterized by UV-Vis absorption, photoluminescence and CIE color coordinate diagram. The optical properties of MEH-PPV/Alq3 solutions have been examined as function of radiation dose over the range of 0-100Gy. It has shown that MEH-PPV/Alq3 solutions are specifically sensitive to X-rays, since the effect of radiation on this organic system is strongly correlated with the efficient spectral overlap between Alq3 emission and the absorption of degraded MEH-PPV, which alters the color and photoemission of MEH-PPV/Alq3 mixtures from red to yellow, and then to green. The rate of this change is more sensitive when MEH-PPV/Alq3 is irradiated in the presence of benzoyl peroxide than when in the presence of hindered phenolic stabilizers, respectively, an accelerator and an inhibitor to activate or inhibit free radical formation. This gives rise to optimize the response curve of the dosimeter. It is clear from the experimental results that organic emissive semiconductors have potential to be used as dedicated and low-cost dosimeters to provide an independent check of beam output of a linear accelerator and therefore to give patients the opportunity to have information on the dose prescription or equipment-related problems a few minutes before being exposed to radiation.
机译:在本文中,我们报告了我们的实验设计,目的是寻找一种智能且易于阅读的剂量计,该剂量计用于检测6MV X射线,从而提高放射肿瘤学中的患者安全性。该设备基于聚(2-甲氧基-5(2'-乙基己氧基)-对亚苯基亚乙烯基)(MEH-PPV),铝-三-(8-羟基喹啉)(Alq3)和添加成分的有机发射溶液通过UV-Vis吸收,光致发光和CIE色坐标图表征。已经检查了MEH-PPV / Alq3溶液的光学性质与0-100Gy范围内的辐射剂量的关系。结果表明,MEH-PPV / Alq3溶液对X射线特别敏感,因为辐射对该有机系统的影响与Alq3发射与降解的MEH-PPV的吸收之间的有效光谱重叠密切相关,从而改变了从红色到黄色,然后到绿色,MEH-PPV / Alq3混合物的颜色和光发射。当在过氧化苯甲酰的存在下照射MEH-PPV / Alq3时,与在受阻酚稳定剂(分别用于激活或抑制自由基形成的促进剂和抑制剂)的存在下进行辐照相比,这种变化的速率更加敏感。这引起优化剂量计的响应曲线。从实验结果可以清楚地看出,有机发射半导体有潜力用作专用的低成本剂量计,以独立检查线性加速器的射束输出,从而使患者有机会了解剂量处方或剂量处方的信息。与设备有关的问题,要在暴露于辐射下几分钟。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号