...
首页> 外文期刊>Medical engineering & physics. >Deformation behavior of the iliotibial tract under different states of fixation
【24h】

Deformation behavior of the iliotibial tract under different states of fixation

机译:不同固定状态下ili胫束的变形行为

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Background and objective: The iliotibial tract (tract) is an important structure for the biomechanics of both the hip and knee joint. While a detailed characterization of its mechanical properties might help to better understand its specific role in the load transfer from the pelvis to femur and tibia, determination of those properties is complicated by its particular structure of thin fibers in the fresh state. Moreover, although the tracts mechanical properties are often derived from cadaveric material chemically fixed with either ethanol or formaldehyde, the influence of such fixation methods remains to be elucidated. Aim of this study was to determine Young's modulus (tensile modulus, YM) of the tract. We hypothesized that either ethanol or formaldehyde fixation would significantly increase the YM compared to the tracts condition in a fresh state. Material and methods: 13 specimens of tract were gained from donators. The ends of the probes were plastinated with resin creating a sharp interface between the clamp and the probe to prevent material slippage. The specimens were measured in their fresh state, under ethanol- and formaldehyde-fixed conditions and re-measured after rinsing with tap water. Results: The YM of the fresh probes averaged 397.3N/mm 2 with a standard deviation (SD) of 151.5N/mm 2. The YM of the ethanol-fixed specimens was significantly higher (673.2N/mm 2, SD 328.5N/mm 2, p0.05). After rinsing with tap water, the YM decreased to 95% of the fresh condition value (377.4N/mm 2, SD 144.5N/mm 2, non-significant change from fresh). After formaldehyde fixation, the YM reached 490.3N/mm 2 (SD 143.0N/mm 2, p0.05). When the formaldehyde-fixed specimens were rinsed, the YM was 114% of the value of the fresh condition (452.6N/mm 2, SD 115.1N/mm 2, non-significant change from fresh). Conclusions: This study found a significant influence of the chemical fixation method on the YM of the IT tract. If such fixation is required, our results suggest using a treatment with ethanol and subsequent rinsing that results in minimal changes to the tracts YM. Furthermore, plastination of the ends of the specimens could be crucial to allow in vitro determination of valid YM of ligaments data that can then be integrated with confidence in further finite element analyses.
机译:背景与目的:胫束是髋关节和膝关节生物力学的重要结构。虽然对其机械性能的详细表征可能有助于更好地了解其在从骨盆到股骨和胫骨的负荷转移中的特定作用,但由于处于新鲜状态的细纤维的特殊结构,使这些性能的确定变得复杂。而且,尽管管道的机械性能通常来自用乙醇或甲醛化学固定的尸体材料,但这种固定方法的影响仍有待阐明。这项研究的目的是确定管道的杨氏模量(拉伸模量,YM)。我们假设与新鲜状态下的烟道条件相比,乙醇或甲醛固定都会显着增加YM。材料和方法:从捐赠者那里获得了13个道标本。探针的末端用树脂塑化,在夹具和探针之间形成了清晰的界面,以防止材料打滑。在乙醇和甲醛固定的条件下,以新鲜状态测量样品,并在用自来水冲洗后重新测量。结果:新鲜探针的YM平均为397.3N / mm 2,标准偏差(SD)为151.5N / mm2。乙醇固定样品的YM显着更高(673.2N / mm 2,SD 328.5N / mm 2,p <0.05)。用自来水冲洗后,YM降至新鲜状态值的95%(377.4N / mm 2,SD 144.5N / mm 2,与新鲜相比无显着变化)。甲醛固定后,YM达到490.3N / mm 2(SD 143.0N / mm 2,p <0.05)。漂洗甲醛固定样品后,YM为新鲜条件值的114%(452.6N / mm 2,SD 115.1N / mm 2,与新鲜相比无显着变化)。结论:这项研究发现化学固定方法对IT道YM有重大影响。如果需要固定,我们的结果建议使用乙醇处理,然后漂洗,以使YM区域变化最小。此外,标本末端的塑化对于体外确定韧带数据的有效YM至关重要,然后可以有信心地将其整合到进一步的有限元分析中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号