Centre of foot pressure (CoP) measures, computed from a force platform, are commonly used to assess individual's postural control during unperturbed stance. The purpose of the present study was to evaluate the effect of the number of trial recordings on the test-retest reliability of CoP measures and to determine the optimum number of trial recordings required to maximise their test-retest reliability. Ten young healthy adults were asked to stand upright, eyes closed, as still as possible on a force platform allowing measuring the CoP displacements. Two sessions of ten 30s trials were performed with 1h rest in between. Intra-class correlation coefficient (ICC) with 95% confidence interval and Bland and Altman analysis were used as statistical method for assessing test-retest reliability of CoP measures. These analyses were conducted on both (1) non-normalized CoP measures and (2) CoP measures normalized relative to the subjects' anthropometric properties (height, weight and body mass index). Results show that ICCs generally increase as the number of trials used to compute CoP measures increases. Interestingly, three 30s trial recordings are sufficient to ensure excellent test-retest reliability of 12 CoP measures widely employed in clinical practice, namely two-dimensional CoP parameters (surface area, range, mean and maximal velocities of the CoP displacements) and one-dimensional mediolateral and anteroposterior CoP parameters (variance, range, mean and maximal velocities). The present findings could have implications in clinical and rehabilitative areas.
机译:从力量平台计算得出的足部压力中心(CoP)量度通常用于评估个人在不受干扰的姿势下的姿势控制。本研究的目的是评估试验记录数对CoP措施的重测信度的影响,并确定使它们的重测信度最大化所需的最佳试验记录数。十名年轻健康的成年人被要求直立,双眼紧闭,尽可能在可测量CoP位移的测力平台上。进行了两次十项30年代试验,每次间隔1小时。使用具有95%置信区间的类内相关系数(ICC)以及Bland和Altman分析作为评估CoP措施重测信度的统计方法。这些分析是针对(1)非标准化CoP量度和(2)相对于受试者的人体测量学特性(身高,体重和体重指数)标准化的CoP量度进行的。结果表明,随着用于计算CoP量度的试验次数的增加,ICC通常也会增加。有趣的是,三个30秒的试验记录足以确保在临床实践中广泛采用的12种CoP量度具有出色的重测可靠性,即二维CoP参数(CoP位移的表面积,范围,平均和最大速度)和一维后外侧和前后CoP参数(方差,范围,平均速度和最大速度)。目前的发现可能对临床和康复领域有影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号