摘要

PURPOSE: A mobile radiography automatic grid alignment system (AGAS) has been developed by modifying a commercially available mobile unit. The objectives of this article are to describe the modifications and operation and to report on the accuracy with which the focal spot is aligned to the grid and the time required to achieve the alignment. METHODS: The modifications include an optical target arm attached to the grid tunnel, a video camera attached to the collimator, a motion control system with six degrees of freedom to position the collimator and x-ray tube, and a computer to control the system. The video camera and computer determine the grid position, and then the motion control system drives the x-ray focal spot to the center of the grid focal axis. The accuracy of the alignment of the focal spot with the grid and the time required to achieve alignment were measured both in laboratory tests and in clinical use. RESULTS: For a typical exam, the modified unit automatically aligns the focal spot with the grid in less than 10 s, with an accuracy of better than 4 mm. The results of the speed and accuracy tests in clinical use were similar to the results in laboratory tests. Comparison patient chest images are presented--one obtained with a standard mobile radiographic unit without a grid and the other obtained with the modified unit and a 15:1 grid. The 15:1 grid images demonstrate a marked improvement in image quality compared to the nongrid images with no increase in patient dose. CONCLUSIONS: The mobile radiography AGAS produces images of significantly improved quality compared to nongrid images with alignment times of less than 10 s and no increase in patient dose.
机译:目的:通过修改市售的移动设备,开发了移动射线照相自动栅格对准系统(AGAS)。本文的目的是描述修改和操作,并报告焦点与网格对准的精度以及实现对准所需的时间。方法:修改包括将光学目标臂连接到网格隧道,将摄像机连接到准直仪,具有六个自由度的运动控制系统,以定位准直仪和X射线管,以及用于控制该系统的计算机。摄像机和计算机确定栅格位置,然后运动控制系统将X射线焦点驱动到栅格焦点轴的中心。在实验室测试和临床使用中都测量了焦点与网格对准的精度以及实现对准所需的时间。结果:对于典型的检查,修改后的单元会在不到10 s的时间内自动将焦点与网格对齐,准确度优于4 mm。临床使用的速度和准确性测试的结果与实验室测试的结果相似。呈现了比较的患者胸部图像-一个是使用不带网格的标准移动放射线照相单元获得的,另一个是使用修改后的单元和15:1网格获得的。与非网格图像相比,15:1网格图像显示出图像质量的显着改善,并且患者剂量没有增加。结论:与非网格图像相比,移动放射线照相AGAS产生的图像质量显着提高,对准时间少于10 s,并且患者剂量没有增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号