We describe here a simple lens system to test the positioning of the field light source and mylar crosshair for radiation therapy linear accelerators. Ideally the light source for the field light and the crosshair should be centered on the axis of rotation of the collimator. The traditional method for testing this coincidence uses the shadow of the crosshair caused by the field light source. The shadow of the crosshair is dependent on the position of both the field light source and mylar crosshair. Geometrically it is possible for the field light source and the mylar crosshair to be off the axis of rotation of the collimator and still cause the shadow of the crosshair to be on the axis of rotation at some distance. Using a lens system the motion of the field light source and crosshair can be observed in sharp focus independently of one another as the collimator is rotated.
机译:我们在这里描述一种简单的透镜系统,以测试场光源和聚酯薄膜十字准线在放射治疗线性加速器中的位置。理想情况下,用于野外照明的光源和十字准线应以准直仪的旋转轴为中心。测试这种重合的传统方法使用由场光源引起的十字准线阴影。十字准线的阴影取决于场光源和聚酯薄膜十字准线的位置。从几何学上讲,场光源和聚酯薄膜十字准线有可能偏离准直仪的旋转轴,而仍然使十字准线的阴影在旋转轴上保持一定距离。使用透镜系统,可以在准直仪旋转时彼此独立地在清晰的焦点上观察场光源和十字准线的运动。