首页> 外文期刊>Medical Physics >Compact monochromatic flash x-ray generator utilizing a disk-cathode molybdenum tube.
【24h】

Compact monochromatic flash x-ray generator utilizing a disk-cathode molybdenum tube.

机译:紧凑的单色闪光X射线发生器,采用盘状阴极钼管。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The high-voltage condensers in a polarity-inversion two-stage Marx surge generator are charged from -50 to -70 kV by a power supply, and the electric charges in the condensers are discharged to an x-ray tube after closing gap switches in the surge generator with a trigger device. The x-ray tube is a demountable diode, and the turbo molecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Clean molybdenum Kalpha lines are produced using a 20 microm-thick zirconium filter, since the tube utilizes a disk cathode and a rod target, and bremsstrahlung rays are not emitted in the opposite direction to that of electron acceleration. At a charging voltage of -70 kV, the instantaneous tube voltage and current were 120 kV and 1.0 kA, respectively. The x-ray pulse widths were approximately 70 ns, and the generator produced instantaneous number of Kalpha photons was approximately 3 x 10(7) photons/cm2 per pulse at 0.5 m from the source of 3.0 mm in diameter.