首页> 外文期刊>Medical Physics >Fast, limited-data photoacoustic imaging for multiplexed systems using a frequency-domain estimation technique.
【24h】

Fast, limited-data photoacoustic imaging for multiplexed systems using a frequency-domain estimation technique.

机译:使用频域估计技术对多路复用系统进行快速,有限数据的光声成像。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: A new frequency-domain estimation algorithm has been developed that uses a priori information to simultaneously improve imaging quality and time resolution in photoacoustic tomography with incomplete data sets. METHODS: The method involves application of a single-stage Wiener optimal filter to augment data sets by interpolation between measurement locations using relationships determined in a reference scan. The filter can be applied in real-time using FFT methods using either fixed or dynamic references and used with any imaging algorithm. The performance of the method is compared to a modified version of constrained backprojection algorithms using simulations and experimental investigations. RESULTS: Simulations demonstrate the effectiveness of the approach for tracking dynamic photoacoustic activity for data sets with limited views (90 degrees) or tomographic views with a reduced number of acquisition angles at any given time (< or = 32). Experimental data of contrast uptake and washout using a 512-element curved transducer with 8:1 electronic multiplexing with the algorithm demonstrate full two-dimensional tomographic imaging with a temporal resolution better than 130 ms. CONCLUSIONS: The estimation algorithm enables high spatial resolution, real-time imaging of dynamic physiological events or volumetric regions for photoacoustic systems employing multiplexing or scanning.
机译:目的:已经开发了一种新的频域估计算法,该算法使用先验信息来同时提高具有不完整数据集的光声层析成像的成像质量和时间分辨率。方法:该方法包括应用单级维纳最优滤波器,以使用参考扫描中确定的关系通过在测量位置之间进行插值来扩充数据集。可以使用FFT方法(使用固定参考或动态参考)实时应用该滤波器,并与任何成像算法一起使用。使用仿真和实验研究,将该方法的性能与约束反投影算法的修改版本进行比较。结果:仿真证明了该方法对于在任何给定时间(<或= 32)具有有限视图(90度)或断层扫描视图且采集角度数量减少的数据集跟踪动态光声活动的有效性。使用带有8:1电子多路复用的512元素弯曲换能器和该算法的造影剂摄取和冲洗实验数据表明,全二维层析成像的时间分辨率优于130毫秒。结论:该估计算法可实现高空间分辨率,动态生理事件或体积区域的实时成像,用于采用多路复用或扫描的光声系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号