OBJECTIVE: To study the importance of a J shape in atrial pacing leads. PATIENTS AND METHODS: We compared in a randomized controlled study acute and chronic results with 2 steroid-eluting, polyurethane, screw-in atrial lead models that differ only in shape. A total of 208 patients were randomized to have implantation of either a straight atrial lead (n = 105) or a J-shaped atrial lead (n = 103). Patients were followed up for 1 year. RESULTS: On implantation, there were no significant differences between leads in rates of failure to implant, implant measurements, number of attempts to achieve an acceptable position, and fluoroscopy times. Before discharge and at 3-month and 1-year follow-up, electrical measurements showed no statistical differences between leads. During the first year after implantation, there were 2.9% early dislodgments (< 1 week after implantation) and 2.9% late dislodgments in the straight lead group (5.9% rate of all dislodgments) vs no dislodgments in the J-shaped lead group (P = .01). There was a trend toward higher rates of exit block and lead malfunction in the J-shaped lead group. Rates of pericardial complications, subclavian/axillary thrombosis, and chronic atrial fibrillation were the same in both groups. CONCLUSIONS: Both leads appear to have an equally favorable performance profile for 1 year of follow-up. The J-shaped lead seems to be more stable and have fewer dislodgments, although it may have a somewhat higher malfunction rate.
机译:目的:研究J形在心房起搏导线中的重要性。患者与方法:我们在一项随机对照研究中比较了两种仅在形状上不同的类固醇洗脱,聚氨酯,旋入式心房铅模型的急性和慢性结果。总共208名患者被随机分配为植入直心房导线(n = 105)或J形心房导线(n = 103)。随访1年。结果:植入时,导线的失败率,植入物测量值,尝试达到可接受位置的次数和透视时间之间无显着差异。在放电前以及在3个月和1年的随访中,电学测量显示导线之间无统计学差异。在植入后的第一年,笔直引线组的早期移位为2.9%(植入后<1周),晚期移位为2.9%(所有移位的比率为5.9%),而J型引线组则无移位(P = .01)。 J形引线组中存在出口阻塞和引线故障率更高的趋势。两组的心包并发症,锁骨下/腋窝血栓形成和慢性心房颤动的发生率相同。结论:在随访的1年中,这两种线索都表现出同样良好的表现。尽管J形引线的故障率可能会更高,但它似乎更稳定并且移位更少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号