A failure analysis of a stop-and-control combined steam valve stem, which failed during service in a thermal power station, was performed by means of optical and electron microscopy techniques. The fractographic observations showed an inter-granular decohesion indicative of a brittle fracture and that the origin of the fracture was located on the nitrided thread of the stem, which thus acted as a stress concentrator. Mechanical tests showed a low toughness of the material, due to a high density of precipitates on grain boundaries, and a heterogeneous austenitic (duplex structure) grain distribution, as revealed by light optical and electron metallographic analysis. Failure was attributed to the low toughness of the material and a nitrided layer on the roots of the threaded zone.
机译:通过光学和电子显微镜技术对停止控制的组合式蒸汽阀杆进行了故障分析,该阀杆在火力发电厂中使用期间发生故障。形貌观察表明,晶间脱粘表明脆性断裂,并且断裂的起源位于茎的渗氮线上,因此起应力集中作用。机械测试表明,由于在晶界上的析出物密度高,材料的韧性低,并且通过光学和电子金相分析发现,奥氏体(双相结构)晶粒分布不均。失败归因于材料的低韧性和螺纹区根部的氮化层。