首页> 外文期刊>Materials and Corrosion >SCC of X-52 and X-60 weldements in diluted NaHCO{sub}3 solutions with chloride and sulfate ions
【24h】

SCC of X-52 and X-60 weldements in diluted NaHCO{sub}3 solutions with chloride and sulfate ions

机译:X-52和X-60焊件在含氯离子和硫酸根离子的稀NaHCO {sub} 3溶液中的SCC

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Stress corrosion cracking tests were performed in both X-52 and X-60 weldments in sodium bicarbonate (NaHCO{sub}3) solutions at 50 ℃ using the Slow Strain Rate Testing (SSRT) technique. Solution concentrations varied between 0.1 to 0.0001 M, and to simulate the NS-4 solution, chloride (Cl{sup}-) and/or sulfate ((SO{sub}4){sup}(2-) ) ions were added to the 0.01 M solution. Tests were complemented with hydrogen permeation measurements and polarization curves. It was found that the corrosion rate, taken as the corrosion current, I{sub}(corr), was maximum in 0.01 M NaHCO{sub}3 and with additions of (SO{sub}4){sup}(2-) ions. Higher or lower solution concentrations or additions of Cl{sup}- alone decreased the corrosion rate of the weldment. The SSC susceptibility, measured as the percentage reduction in area, was maximum in 0.01M NaHCO{sub}3. Higher or lower solution concentrations of additions of Cl{sup}- or (SO{sub}4){sup}(2-) decreased the SCC susceptibility of the weldment. The amount of hydrogen uptake for the weldment was also highest in 0.01 M NaHCO{sub}3 solution, but it was minimum with the addition of Cl{sup}- or (SO{sub}4){sup}(2-) ions. Thus, the most likely mechanism for the cracking susceptibility of X-52 and X-60 weldments in diluted NaHCO{sub}3 solutions seems to be hydrogen-assisted anodic dissolution.
机译:使用慢应变速率测试(SSRT)技术在50℃的碳酸氢钠(NaHCO {sub} 3)溶液中对X-52和X-60焊件进行了应力腐蚀开裂测试。溶液浓度在0.1到0.0001 M之间变化,并且为了模拟NS-4溶液,向其中添加了氯离子(Cl {sup}-)和/或硫酸盐((SO {sub} 4){sup}(2-))离子0.01 M溶液。测试辅以氢渗透测量和极化曲线。发现以腐蚀电流I {sub}(corr)为基准的腐蚀速率在0.01 M NaHCO {sub} 3中最大,并添加(SO {sub} 4){sup}(2-)离子。更高或更低的溶液浓度或单独添加Cl {sup}-会降低焊件的腐蚀速率。在0.01M NaHCO {sub} 3中,以面积减少百分比衡量的SSC敏感性最高。 Cl {sup}-或(SO {sub} 4){sup}(2-)添加的溶液浓度较高或较低,可降低焊件的SCC敏感性。在0.01 M NaHCO {sub} 3溶液中,焊件的氢吸收量也最高,但是在添加Cl {sup}-或(SO {sub} 4){sup}(2-)离子后,氢的吸收量最小。 。因此,在稀释的NaHCO {sub} 3溶液中X-52和X-60焊件开裂敏感性的最可能机制似乎是氢辅助阳极溶解。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号