首页> 外文期刊>Materials and Corrosion >On the measurement of the polarisation resistance of reinforcing steel with embedded sensors: A comparative study
【24h】

On the measurement of the polarisation resistance of reinforcing steel with embedded sensors: A comparative study

机译:嵌入式传感器测量钢筋的极化电阻的比较研究

获取原文
获取原文并翻译 | 示例
           

摘要

On site measurement of durability parameters with permanent monitoring systems has been recognised as an important source of information for the development of reliable models to predict the lifetime of reinforced concrete structures. In this study, four electrochemical techniques were applied to determine the polarisation resistance (Rp) of steel embedded in mortar to select the best technique to be used in the development of embedded sensors for corrosion rate monitoring. It could be concluded that, if an adequate time scale to perform each measurement is used, all the techniques lead to the same Rp value within a known experimental error. However, the potentiostatic pulse technique presents some advantages to be used in the development of embedded sensors because it is fast, does not require sophisticated equipment or data analysis, and allows the simultaneous evaluation of the Rp and electrical resistance between the rebar and the reference electrode.
机译:使用永久监控系统对耐久性参数进行现场测量已被认为是开发可靠模型以预测钢筋混凝土结构寿命的重要信息来源。在这项研究中,应用了四种电化学技术来确定埋入砂浆中的钢的极化电阻(Rp),以选择最佳技术来开发用于监测腐蚀速率的嵌入式传感器。可以得出结论,如果使用了足够的时间尺度来执行每个测量,则所有技术都会在已知的实验误差范围内产生相同的Rp值。但是,恒压脉冲技术具有一些优点,可用于嵌入式传感器的开发,因为它速度快,不需要复杂的设备或数据分析,并且可以同时评估钢筋和参比电极之间的Rp和电阻。