Influence of chloride and moisture content on steel rebar corrosion in concrete

机译:氯和水分含量对混凝土中钢筋腐蚀的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Reinforced mortar samples were exposed in humidity chambers with different relative humidity or exposed in cyclic moisture conditions. The rebars were in an as received condition meaning that the preexisting oxide scale were intact. The lowest chloride concentration that initiated corrosion was 1% Cl- by mass of cement, corrosion was then observed for samples exposed at 97% relative humidity. It is suggested that the corrosion rate decreases when samples are exposed to a relative humidity lower than 97%. The results indicate that threshold levels should be evaluated at rather humid conditions (97%) despite the fact that the maximum corrosion rate at higher chloride levels is observed in the interval 91-94%. For samples exposed to cyclic moisture conditions, a lower chloride concentration was needed to initiate corrosion compared to samples exposed in static moisture conditions.
机译:将增强砂浆样品暴露在具有不同相对湿度的湿度室中,或暴露在循环湿度条件下。钢筋处于接收状态,这意味着预先存在的氧化皮是完整的。引发腐蚀的最低氯化物浓度为水泥质量的1%Cl-,然后在相对湿度为97%的情况下观察到腐蚀。建议当样品暴露于低于97%的相对湿度时腐蚀速率降低。结果表明,尽管在91-94%的区间内观察到了较高氯化物含量下的最大腐蚀速率,但仍应在相当潮湿的条件下(97%)评估阈值水平。对于暴露在周期性潮湿条件下的样品,与暴露在静态潮湿条件下的样品相比,需要较低的氯化物浓度来引发腐蚀。