首页> 外文期刊>Materials and Corrosion >Experience of superheater tubes in municipal waste incineration plant
【24h】

Experience of superheater tubes in municipal waste incineration plant

机译:城市垃圾焚烧厂过热器管的使用经验

获取原文
获取原文并翻译 | 示例
           

摘要

Two years after the start of operations at the Tokachi Association for Municipal Waste Disposal and Treatment Services municipal waste incineration plant (name: Kuririn Center), which generates 400℃ steam, an investigation of the plant's superheater tubes was conducted. The investigation consisted primarily of analyzing ash deposits, measuring tube wall thickness loss and observing tube sections after removal. The concentration of Cl in the deposited ash was found to increase as the temperature of the gas rose, and the amount of deposited ash tended to increase as the temperature of the gas rose. Tube damage consisted primarily of a uniform loss in thickness. Intergranular corrosion and other local corrosion was not observed. The results of thickness-loss measurements showed that, after approximately two years in operation, tubes (SUS310) lost a maximum of 0.45 mm in thickness due to high-temperature corrosion in locations where the steam temperature reached 400 ℃. Superheater tubes were also apparently damaged from the effects of a soot blower, resulting in an observed maximum loss of 0.9 mm thickness after approximately two years. Furthermore, the rate of thickness loss tended to increase after one year had passed.
机译:十胜城市垃圾处理和处理服务协会开始运作的城市垃圾焚化厂(名称:Kuririn中心)运行两年后,产生400℃的蒸汽,并对该厂的过热管进行了调查。该调查主要包括分析灰烬沉积,测量管壁厚度损失以及观察去除后的管截面。发现沉积灰分中Cl的浓度随着气体温度的升高而增加,并且沉积灰烬的量倾向于随气体温度的升高而增加。管的损坏主要包括厚度的均匀损失。没有观察到晶间腐蚀和其他局部腐蚀。厚度损失的测量结果表明,在运行大约两年后,由于蒸汽温度达到400℃的位置受到高温腐蚀,管(SUS310)的最大厚度损失仅为0.45毫米。过热器管显然也受到吹灰器的损坏,导致大约两年后观察到的最大损失为0.9毫米。此外,经过一年后厚度损失率趋于增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号