Improved reproducibility of right ventricular volumes and function estimation from cardiac magnetic resonance images using level-set models.

机译:使用水平集模型提高了右心室容积的重现性,并从心脏磁共振图像估计了功能。

获取原文
获取原文并翻译 | 示例
           

摘要

This study aims to assess whether an alternative method, that is based on volumetric surface detection (VoSD) without tracing and is totally free of geometric assumptions, can improve the reproducibility of right ventricular (RV) volume quantification from cardiac magnetic resonance (CMR) images, in comparison with a conventional disk-area technique. In a sample of 23 patients, with wide variability of RV end-diastolic volume (EDV: 47-131 ml), end-systolic volume (ESV: 20-76 ml), and ejection fraction (EF: 29-73%), using the standard method (Argus, Siemens) as the reference, the VoSD method showed good agreement for EDV, ESV, and EF estimations (correlation coefficient: 0.91, 0.94, and 0.94; Bland-Altman biases: 1 ml, 1 ml, and 0%; limits of agreement: +/-16 ml, +/-11 ml, and +/-11%, respectively). An analysis of the reproducibility of the two methods showed lower intraobserver variability for the VoSD method than for the conventional method, as evidenced by the coefficient of variability (CoV) values (2-6% vs. 8-15%; P < 0.05). In addition, the VoSD method showed improved interobserver reproducibility (7-10% vs. 8-15%), but the difference was statistically significant only for EF estimation variability (8 vs. 15%, P < 0.05). In conclusion, the newly developed VoSD technique allows accurate measurements of RV volumes and function, and appears to be more reproducible than the conventional methodology.
机译:这项研究旨在评估基于体表检测(VoSD)而无需追踪并且完全没有几何假设的替代方法是否可以提高心脏磁共振(CMR)图像对右心室(RV)体积定量的重现性与传统的磁盘区域技术相比。在23名患者的样本中,RV舒张末期容积(EDV:47-131毫升),收缩末期容积(ESV:20-76毫升)和射血分数(EF:29-73%)差异很大,使用标准方法(Argus,Siemens)作为参考,VoSD方法对于EDV,ESV和EF估计显示出良好的一致性(相关系数:0.91、0.94和0.94; Bland-Altman偏差:1 ml,1 ml和0%;一致性限制:分别为+/- 16 ml,+ /-11 ml和+/- 11%)。两种方法的重现性分析表明,VoSD方法的观察者内部变异性比常规方法低,如变异系数(CoV)值所证明的(2-6%对8-15%; P <0.05) 。此外,VoSD方法显示出更好的观察者间可重复性(7-10%对8-15%),但差异仅在EF估计变异性上具有统计学意义(8对15%,P <0.05)。总而言之,新开发的VoSD技术可以精确测量RV的体积和功能,并且比传统方法更具可重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号