首页> 外文期刊>Canadian journal of anesthesia: Journal canadien d'anesthesie >Subarachnoid lumbar drains: a case series of fractured catheters and a near miss.
【24h】

Subarachnoid lumbar drains: a case series of fractured catheters and a near miss.

机译:蛛网膜下腔腰部引流管:一系列病例,导管破裂,几乎未命中。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: Lumbar subarachnoid catheters for cerebrospinal fluid (CSF) drainage (lumbar drains) are indicated for several medical and surgical conditions. A number of complications can occur from the placement of this type of catheter, including catheter breakage from excessive traction or shearing over the Tuohy needle. CLINICAL FEATURES: Five cases of lumbar subarachnoid catheter breakage/shearing and catheter fragment retention, as well as one near miss, were identified over a one-year period at a single institution. All (n = 6) patients were undergoing neurosurgical procedures. Four patients required surgical retrieval of the catheter fragments. No patient experienced log-term neurological sequelae. DISCUSSION: From these experiences, the following risks factors for catheter rupture are identified: 1) intentional or accidental retraction of the catheter through the needle during placement; 2) faulty use of the guidewire; or 3) use of excessive force during removal of the catheter. Methods to prevent such complications are suggested, including minimal use, or complete avoidance of a guidewire.
机译:目的:用于多种医学和外科手术条件的腰椎蛛网膜下腔导管用于脑脊液(CSF)引流。放置这种类型的导管可能会导致许多并发症,包括由于过度牵引或在Tuohy针头上受到剪切而导致导管断裂。临床特征:在单个机构一年的时间内,发现了5例腰椎蛛网膜下腔导管断裂/剪切和导管碎片保留以及1例未命中的病例。所有(n = 6)患者均接受了神经外科手术。四名患者需要手术取回导管碎片。没有患者经历对数期神经系统后遗症。讨论:根据这些经验,确定了以下导致导管破裂的危险因素:1)在放置过程中有意或无意地使导管通过针头缩回; 2)导丝使用不当;或3)拔除导管时用力过大。建议采取预防此类并发症的方法,包括尽量少用或完全避免使用导丝。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号