首页> 外文期刊>Fresenius' Journal of Analytical Chemistry >Development of clenbuterol reference materials: lyophilized bovine eye samples free of clenbuterol (CRM 673) and containing clenbuterol (CRM 674). Part 1. Preparation, homogeneity and stability
【24h】

Development of clenbuterol reference materials: lyophilized bovine eye samples free of clenbuterol (CRM 673) and containing clenbuterol (CRM 674). Part 1. Preparation, homogeneity and stability

机译:开发克仑特罗标准物质:冻干的不含克仑特罗(CRM 673)且含有克仑特罗(CRM 674)的牛眼样品。第1部分。制备,均质性和稳定性

获取原文
获取原文并翻译 | 示例
           

摘要

Within the EU Standards, Measurement and Testing Program (SMT) two clenbuterol reference materials (RMs) were developed. Since clenbuterol readily acumulates and is slowly depleted from pigmented tissues such as the retina, homogenized eye liquid content is the most sensitive tissue for the detection of clenbuterol misuse. Therefore, both of the RMs were produced from bovine eye matrix: a negative control - RM 673 eye reference material, clenbuterol free (< 0.50 mug/kg eye matrix) and a positive - RM 674 eye reference material containing clenbuterol (approx 10 mug/kg eye matrix). Eyes were sampled from 103 German Simmental cattle and the inner liquid content was homogenized to a wet homogenized liquid content (HLC). This clenbuterol negative pool was divided into two sub-pools, one of which was spiked with clenbuterol to a final concentration of 10 mug clenbuterol/kg HLC. Of each pool exactly 2.0 +- 0.01 g (+- 0.5%) portions were weighted into 790 containers. Lyophilization of the 1580 containers was performed inone batch. Parameters for the filling of containers, dry matter content, and residual moisture were in accordance with EU requirements. A three-year stability study and two homogeneity studies at various storage temperatures (-60 deg C, -20 deg C, + 4 deg C, +20 deg C, and 37 deg C) were performed. Low variation was observed within all of the homogeneity studies, proving that each of the RMs were homogeneous and that this was independent of storage temperature and storage time.In the stability studies, measured clenbuterol concentrations remained constant for RM 673 under the detection limit at 0.15 +- 0.01 mug clenbuterol equivalent/kg HLC (n = 110) and were also constant for RM 674 at 11.21 +- 0.15 mug clenbuterol/kg HLC (n = 150; measured as duplicates). These studies demonstrate that clenbuterolcan be successfully produced. Based on the results described above, it is concluded that both RMs may be suitable as candidates for certification.
机译:在欧盟标准,测量和测试计划(SMT)中,开发了两种盐酸克伦特罗标准物质(RM)。由于盐酸克伦特罗容易积聚并逐渐从色素组织(例如视网膜)中耗尽,因此均匀的眼液含量是检测克仑特罗滥用的最敏感组织。因此,两种RM均由牛眼基质制成:阴性对照-RM 673眼参材料,不含瘦肉精(<0.50杯/ kg眼基质)和阳性-RM 674含参苯酸甘油的眼参材料(约10杯/公斤眼矩阵)。从103只德国西门塔尔牛身上取样,将内部液体含量均质化为湿均质液体含量(HLC)。盐酸克伦特罗负离子池分为两个子池,其中一个子池加入克仑特罗,最终浓度为10杯克仑特罗/ kg HLC。在每个池中,精确地将2.0±0.01g(±0.5%)的部分称重到790个容器中。 1580个容器的冻干分批进行。容器填充,干物质含量和残留水分的参数符合欧盟要求。在各种存储温度下(-60摄氏度,-20摄氏度,+ 4摄氏度,+ 20摄氏度和37摄氏度)进行了为期三年的稳定性研究和两项均质性研究。在所有同质性研究中均观察到低变化,证明每个RM均一且独立于储存温度和储存时间。在稳定性研究中,在0.15的检出限下,测得的克伦特罗浓度对于RM 673保持恒定±-0.01克仑特罗当量/ kg HLC(n = 110),并且对于RM 674也恒定在11.21 +-0.15克仑特罗/ kg HLC(n = 150;重复测量)。这些研究表明,克仑特罗可以成功生产。根据上述结果,可以得出结论,两个RM都适合作为认证的候选人。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号