Early postoperative changes of the foveal surface in epiretinal membranes: Comparison of 23-gauge macular surgery with air vs. balanced salt solution

机译:视网膜前膜中央凹表面的早期术后变化:比较23号黄斑部手术与空气和平衡盐溶液的比较

获取原文
获取原文并翻译 | 示例

摘要

Objective: To analyze the foveal surface using binary image analysis after spectral-domain optical coherence tomography (SD-OCT) following 23-gauge macular surgery in epiretinal membranes (ERM) using either air tamponade (AIR) or balanced salt solution (BSS). Methods: One hundred twenty-four eyes (124 patients) with ERM that had undergone membrane peeling with installation of air or BSS were analyzed retrospectively. Ophthalmic examination was performed at baseline and 3 months. Outcome measures: The foveal area and surface symmetry, area matched thickness, area matched contour, and best-corrected visual acuity (BCVA). The OCT images were analyzed after binary conversion with ImageJ software. Results: Eighty eyes (80 patients) of 124 screened patients were included (AIR group: 39 patients, BSS group: 41 patients). Median follow-up time was 14 weeks (range, 9-19 weeks). Three months after surgery, the median horizontal area decreased significantly in both groups (p<0.0001). At follow-up, the foveal surface symmetry values for the BSS group (median, 22.73 μm, range, 0-153) were significantly lower than for the AIR group (median, 23.95 μm, range, 0-160.43) (p<0.0001). The area-matched thickness increased significantly in both groups (p<0.001). The AIR group showed a significant increase of the area matched contour for the nasal located measurement-areas N1 (p<0.0003), N2 (p<0.0079), N3 (p<0.007). The BSS group showed a significant increase of the area-matched contour for the measurement areas N1 (p<0.019), N2 (p<0.0014), and N4 (p<0.022). After surgery, median BCVA for both groups increased significantly to 0.3 logMAR. Conclusions: The analysis of early contour changes after ERM surgery was technically possible. Long-term data have to be looked at before the clinical impact of this methodology can be estimated. Although there were no big differences between both groups (AIR vs. BSS), this could change within a longer and more representative follow-up.
机译:目的:在使用射频填塞剂(AIR)或平衡盐溶液(BSS)对视网膜前膜(ERM)进行23号黄斑手术后,在光谱域光学相干断层扫描(SD-OCT)后使用二值图像分析技术分析中央凹表面。方法:回顾性分析124例124眼ERM患者,这些患者在安装空气或BSS后进行了膜剥离。在基线和3个月时进行眼科检查。结果测量:中央凹区域和表面对称性,区域匹配的厚度,区域匹配的轮廓以及最佳矫正视力(BCVA)。使用ImageJ软件进行二进制转换后,分析了OCT图像。结果:筛选出124例筛查患者的80只眼(80例)(AIR组:39例,BSS组:41例)。中位随访时间为14周(9-19周)。术后三个月,两组中位水平水平面积均显着下降(p <0.0001)。随访时,BSS组的中央凹表面对称性值(中位数为22.73μm,范围为0-153)显着低于AIR组(中位数为23.95μm,范围为0-160.43)(p <0.0001) )。两组的面积匹配厚度均显着增加(p <0.001)。 AIR组显示鼻位置测量区域N1(p <0.0003),N2(p <0.0079),N3(p <0.007)的区域匹配轮廓显着增加。 BSS组显示出测量区域N1(p <0.019),N2(p <0.0014)和N4(p <0.022)的区域匹配轮廓显着增加。手术后,两组的BCVA中位数均显着增加至0.3 logMAR。结论:ERM手术后早期轮廓变化的分析在技术上是可能的。在评估此方法的临床影响之前,必须查看长期数据。尽管两组之间(AIR与BSS)之间没有太大差异,但可以在更长且更具代表性的随访中改变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号