首页> 外文期刊>Gait & posture >Short-distance walking speed tests in people with Parkinson disease: Reliability, responsiveness, and validity
【24h】

Short-distance walking speed tests in people with Parkinson disease: Reliability, responsiveness, and validity

机译:帕金森氏病患者的短距离步行速度测试:可靠性,反应性和有效性

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: The aims of this study were to determine test-retest reliability and responsiveness of short-distance walking speed tests for persons with Parkinson disease (PD). Discriminant and convergent validity of walking speed tests were also examined. Methods: Eighty-eight participants with PD (mean age, 66 years) with mild to moderate severity (stages 1-4 on the Hoehn and Yahr Scale) were tested on medications. Measures of activity included the comfortable and fast 10-m walk tests (CWT, FWT), 6-min walk test (6MWT), mini balance evaluations systems test (mini-BEST Test), fear of falling (FoF), and the Activity-Specific Balance Confidence Scale (ABC). The mobility subsection of the PD quality of life-39 (PDQ39-M) served as a participation-based measure. Results: Test-retest reliability was high for both walking speed measures (CWT, ICC2,1=0.98; FWT, ICC2,1=0.99). Minimal detectable change (MDC95) for the CWT and FWT was 0.09m/s and 0.13m/s respectively. Participants at Hoehn & Yahr levels 3/4 demonstrated significantly slower walking speed with the CWT and FWT than participants at Hoehn & Yahr levels 1 and 2 (P.01). The CWT and FWT were both significantly (P≤.002) correlated with all activity and participation-based measures. Conclusions: Short-distance walking speed tests are clinically useful measures for persons with PD. The CWT and FWT are highly reliable and responsive to change in persons with PD. Short distance walking speed can be used to discriminate differences in gait function between persons with mild and moderate PD severity. The CWT and FWT had moderate to strong associations with other activity and participation based measures demonstrating convergent validity.
机译:目的:本研究的目的是确定帕金森病(PD)患者的短距离步行速度测试的重测信度和响应度。还检查了步行速度测试的判别和收敛效度。方法:对88位PD(平均年龄66岁),轻度至中度(Hoehn和Yahr量表的1-4期)的参与者进行了药物测试。活动度量包括舒适快速的10分钟步行测试(CWT,FWT),6分钟步行测试(6MWT),小天平评估系统测试(mini-BEST测试),跌落恐惧(FoF)和活动-特定余额置信量表(ABC)。 PD生活质量39(PDQ39-M)的流动性小节用作基于参与的度量。结果:两种步行速度测量的重测信度均很高(CWT,ICC2,1 = 0.98; FWT,ICC2,1 = 0.99)。 CWT和FWT的最小可检测变化(MDC95)分别为0.09m / s和0.13m / s。 Hoehn&Yahr级别3/4的参与者表现出CWT和FWT行走速度明显比Hoehn&Yahr级别1和2的参与者慢(P <.01)。 CWT和FWT都与所有活动和基于参与的措施均显着相关(P≤.002)。结论:短距离步行速度测试是针对PD患者的临床有用措施。 CWT和FWT是高度可靠的,并且对PD患者的变化敏感。短距离步行速度可用于区分轻度和中度PD严重程度者之间的步态功能差异。 CWT和FWT与其他活动和基于参与的措施之间具有中等至强的关联性,证明了聚合效度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号