首页> 外文期刊>Experimental Thermal and Fluid Science: International Journal of Experimental Heat Transfer, Thermodynamics, and Fluid Mechanics >Experimental study of soot particle fouling on ribbed plates: Applicability of the critical local wall shear stress criterion
【24h】

Experimental study of soot particle fouling on ribbed plates: Applicability of the critical local wall shear stress criterion

机译:肋板上烟尘颗粒结垢的实验研究:局部局部壁面剪应力准则的适用性

获取原文
获取原文并翻译 | 示例
           

摘要

This article examines the notion of critical wall shear stress as the key control parameter of the local fouling removal process. In this study, an experimental setup was developed for measuring fouling on enhanced surfaces. Specifically, the experimental configuration consists of a forced convection plate heat exchanger containing a one-pass rectangular channel with two ribbed plates arranged in a symmetrically staggered manner. The exhaust gases flow by the rib-roughened sides of the plates, and the flat sides can be cooled with water from the independent external coolant circuit. As a result of soot particle deposition from exhaust gases, a layer of fouling is deposited over the ribs. After asymptotic conditions were reached during the tests, detailed fouling thickness measurements were conducted. The dimensionless particle relaxation time during these tests was determined to be in the range of 0.3-10. The measurements were then complemented with a numerical analysis. In particular, the local wall shear stress was calculated using a commercial computational fluid dynamics (CFDs) software package. The fouling thickness profiles deposited over the ribs and the local critical shear stress values were compared and discussed for two different geometries. The results obtained clearly support the idea that critical wall shear stress is an appropriate criterion for facilitating the understanding of the local behaviour of fouling deposits.
机译:本文研究了临界壁剪应力的概念,该概念是局部结垢清除过程的关键控制参数。在这项研究中,开发了一种用于测量增强表面结垢的实验装置。具体而言,实验配置由强制对流板式热交换器组成,该热交换器包含一个单向矩形通道,该通道具有两个对称对称排列的肋板。废气流经板的肋状粗糙面,并且可以用独立的外部冷却剂回路中的水冷却平坦面。由于废气中的烟尘颗粒沉积,结垢层沉积在肋上。在测试过程中达到渐近条件后,进行了详细的结垢厚度测量。在这些测试中,无因次粒子松弛时间被确定为在0.3-10之间。然后对测量结果进行数值分析。特别是,使用商业计算流体力学(CFD)软件包计算了局部壁面剪应力。比较并讨论了两种不同几何形状的沉积在肋板上的结垢厚度分布图和局部临界切应力值。所获得的结果清楚地支持了以下观点:临界壁剪应力是促进理解结垢沉积物局部行为的适当标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号