Comparison of higher-order aberrations after LASIK using disposable microkeratome 130 and 90 micron heads.

机译:使用一次性微型角膜刀130和90微米头进行LASIK手术后高阶像差的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE. To analyze and compare higher-order aberrations (HOAs) in cases of laser in situ keratomileusis (LASIK) flaps made using the Moria M2 disposable 130-micronm head with those made using the 90-micronm head. METHODS. Consecutive prospective comparative clinical trial. Ninety-four consecutive eyes of 48 patients were enrolled in this study. They were divided into two equal groups of 47 eyes that underwent wavefront-guided LASIK using VISX CustomVue (VISX, Santa Clara, CA) system. Corneal flap was created using the disposable Moria M2 130 micronm in the first group and the 90 micronm head in the second one. All patients were followed up for 6 months. Wavefront aberrations were measured at baseline, 1 month, and 6 months after surgery using the WaveScan (VISX Inc.) aberrometer. Root mean square (RMS) of HOAs, coma, and spherical aberration (SA) values were analyzed and compared in the two groups. RESULTS. At 6 months, values of RMS of HOAs, coma, and SA obtained from the 130-micronm head group were 0.32+/-0.10 micronm, 0.20+/-0.11 micronm, and 0.18+/-0.08 micronm, respectively. Values of RMS of HOAs, coma, and SA obtained from 90-micronm head group were 0.33+/-0.12 micronm, 0.19+/-0.10 micronm, and 0.15+/-0.08 micronm, respectively. Analyzing the data obtained revealed no statistically significant differences between the two groups. In each group, there was a significant decay of higher-order RMS and coma values from 1 month to 6 months. CONCLUSIONS. HOAs following use of Moria M2 disposable 90 micronm head are similar to those arising following use of the 130 micronm.
机译:目的。若要分析和比较使用Moria M2一次性130微米头制作的激光原位角膜磨镶术(LASIK)皮瓣和使用90微米头制作的皮瓣的高阶像差(HOA)。方法。连续的前瞻性比较临床试验。本研究共纳入48位患者的94眼。将他们分为两组,每组47眼,使用VISX CustomVue(VISX,加利福尼亚州圣克拉拉)系统进行波前引导LASIK手术。第一组使用一次性的Moria M2 130 micronm,第二组使用90 micronm头制作角膜瓣。所有患者均获随访6个月。使用WaveScan(VISX Inc.)像差仪在基线,手术后1个月和6个月时测量波前像差。分析并比较两组的HOA均方根(RMS),彗差和球差(SA)值。结果。在6个月时,从130微米纳米头组获得的HOA,昏迷和SA的RMS值分别为0.32 +/- 0.10微米,0.20 +/- 0.11微米和0.18 +/- 0.08微米。从90微米纳米头组获得的HOA,彗差和SA的RMS值分别为0.33 +/- 0.12微米,0.19 +/- 0.10微米和0.15 +/- 0.08微米。分析获得的数据表明,两组之间在统计学上没有显着差异。在每个组中,从1个月到6个月,高阶RMS和昏迷值都有显着衰减。结论。使用Moria M2一次性90微米头后的HOA与使用130微米后所产生的HOA类似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号