...
首页> 外文期刊>Experimental Gerontology >Age-associated impairement in endpoint accuracy of goal-directed contractions performed with two fingers is due to altered activation of the synergistic muscles
【24h】

Age-associated impairement in endpoint accuracy of goal-directed contractions performed with two fingers is due to altered activation of the synergistic muscles

机译:与两个手指进行的目标定向收缩的终点准确性相关的年龄相关损伤是由于协同肌肉的激活改变

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this study was to determine whether older adults compared with young adults exhibit impaired end-point accuracy during a two-finger task due to altered activation of the contributing synergistic muscles. Nine young (21.3. years. ±. 1.6. years, 4 men) and 9 older (73.1. years. ±. 6.4. years, 5 men) were instructed to accurately match the center of a target with concurrent abduction of the index and little fingers (synergistic two-finger task). The target comprised of 20% MVC and 200. ms. Visual feedback of the force trajectory and target was provided 1. s after each trial. Subjects completed 40 trials and the last 10 were used for analysis. Endpoint accuracy was quantified as the normalized deviation from the target in terms of peak force (peak force error), time-to-peak force (time-to-peak force error), and a combination of the two (overall error). Motor output variability was quantified as the standard deviation and coefficient of variation (CV) of peak force and time to peak force. The neural activation of the involved synergist muscles (first dorsal interosseus (FDI) and abductor digiti minimi (ADM)) was quantified with the electromyography (EMG) amplitude (root mean square) and its frequency structure (wavelet analysis). Older adults exhibited significantly greater peak force (46.7. ±. 10% vs. 24.9. ±. 3.2%) and overall endpoint error (68.5. ±. 9.7% vs. 41.7. ±. 4.3%), whereas the time to peak force error was similar for the two age groups. Older adults also exerted greater peak force variability than young adults, as quantified by the CV of peak force (34.3. ±. 3.5% vs. 24.1. ±. 2.3%). The greater peak force error in older adults was associated with changes in the activation of the ADM muscle but not the FDI. Specifically, greater peak force error was associated with greater power from 13-30. Hz and lesser power from 30-60. Hz. These results, therefore, suggest that older adults compared with young adults exhibit impaired endpoint force accuracy during a two finger task because of altered activation of one of the synergist muscles.
机译:这项研究的目的是确定在两个手指的任务过程中,老年人与年轻人相比是否由于受损的协同肌肉激活改变而表现出降低的终点准确性。指示9名年轻(21.3。岁。±。1.6。岁,男4名)和9岁(73.1岁。±。6.4。岁,5名男)准确匹配目标中心并同时绑架指数和小手指(两个手指协同工作)。目标包括20%MVC和200. ms。每次试验后1. s提供力轨迹和目标的视觉反馈。受试者完成了40次试验,最后10次用于分析。终点精度被量化为相对于目标的标准化偏差,以峰值力(峰值力误差),峰时力(峰时力误差)和二者的组合(总误差)表示。电动机输出的可变性被量化为峰值力和到峰值力的时间的标准偏差和变异系数(CV)。通过肌电图(EMG)振幅(均方根)及其频率结构(小波分析)量化累及的协同增肌(第一背骨间肌(FDI)和指外展肌(ADM))的神经激活。老年人表现出明显更大的峰值力(46.7。±.10%vs. 24.9。±。3.2%)和总体终点误差(68.5。±。9.7%vs. 41.7。±.4.3%),而达到峰值力的时间两个年龄组的错误相似。老年人的峰值力变异性也比年轻人大,这由峰值力的CV量化(34.3。±。3.5%vs. 24.1。±。2.3%)。老年人中较大的峰值力误差与ADM肌肉激活的变化有关,而与FDI的激活无关。具体而言,更大的峰值力误差与13-30的更大功率相关。 Hz和30-60之间的较小功率。赫兹。因此,这些结果表明,由于协同肌肉之一的激活改变,在两指任务期间,老年人与年轻人相比端点力准确性受损。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号