Non-invasive measurement of blood hematocrit in artery

机译:非侵入性测量动脉血细胞比容

获取原文
获取原文并翻译 | 示例
           

摘要

Objective:The goal of this work was to develop a clinically applicable method for non-invasive acoustic determination of hematocrit in vivo.Methods:The value of hematocrit (HCT) was determined initially in vitro from the pulse-echo measurements of acoustic attenuation.The testing was carried out using a laboratory setup with ultrasound transducer operating at 20 MHz and employing human blood samples at the temperature of 37 deg C.The attenuation coefficient measurements in blood in vitro and in vivo were implemented using multi-gated (128-gates),20 MHz pulse Doppler flow meter.The Doppler signal was recorded in the brachial artery.Both in vitro and in vivo HCT data were compared with those obtained using widely accepted,conventional centrifuge method.Results:The attenuation coefficient in vitro was determined from the measurements of 168 samples with hematocrit varying between 23.9 and 51.6%.Those experiments indicated that the coefficient increased linearly with hematocrit.The HCT value was obtained from the 20 MHz data using regression analysis.The attenuation (() was determined as a 42.14+1.02 centre dot HCT (Np/m).The corresponding standard deviation (SD),and the correlation coefficient were calculated as SD=2.4 Np/m,and R=0.9,(p < 0.001 ),respectively The absolute accuracy of in vivo measurements in the brachial artery was determined to be within +-5% HCT.Conclusions:The method proposed appears to be promising for in vivo determination of hematocrit as 5% error is adequate to monitor changes in patients in shock or during dialysis.It was found that the multigate system largely simplified the placement of an ultrasonic probing beam in the center of the blood vessel.Current work focuses on enhancing the method's applicability to arbitrary selected vessels and reducing the HCT measurement error to well below 5%.
机译:目的:这项工作的目的是开发一种在临床上可用于体内非侵入性声学测定血细胞比容的方法。方法:血细胞比容(HCT)的值最初是通过声衰减的脉冲回波测量在体外确定的。使用实验室传感器进行测试,超声换能器在20 MHz频率下操作,并在37摄氏度的温度下使用人体血液样本。体外和体内血液的衰减系数测量是使用多门(128门)进行的20 MHz脉冲多普勒流量计。在肱动脉中记录多普勒信号。将体外和体内HCT数据与使用广泛接受的常规离心方法获得的结果进行比较。 168份血细胞比容在23.9%至51.6%之间变化,这些实验表明该系数随血细胞比容呈线性增加。通过回归分析从20 MHz数据获得ue。衰减(()确定为42.14 + 1.02中心点HCT(Np / m)。相应的标准偏差(SD)和相关系数计算为SD =确定肱动脉的体内测量的绝对准确度分别在2.4 Np / m和R = 0.9(p <0.001)HCT内。结论:所提出的方法似乎有希望体内测定血细胞比容为5%的误差足以监测休克或透析患者的变化,发现多门系统大大简化了超声探查束在血管中心的放置,目前的工作重点是增强该方法适用于任意选择的容器,并将HCT测量误差降低到5%以下。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号